Direct measurements of gravel thermal properties are usually quite challenging to be performed in laboratory, due to the very coarse sediments size. As a consequence, the reference thermal values provided by literature for gravels are quite limited and dispersed. A guarded hot plate Taurus Instruments TLP 800, usually used for measuring the thermal conductivity of buildings materials, was slightly modified in order to measure the thermal conductivity of some gravel samples. The tests were performed both in dry and wet conditions. The paper presents the first obtained results.
Laboratory Measurements of Gravel Thermal Conductivity: An Update Methodological Approach
DALLA SANTA, GIORGIA;GALGARO, ANTONIO;CULTRERA, MATTEO;
2017
Abstract
Direct measurements of gravel thermal properties are usually quite challenging to be performed in laboratory, due to the very coarse sediments size. As a consequence, the reference thermal values provided by literature for gravels are quite limited and dispersed. A guarded hot plate Taurus Instruments TLP 800, usually used for measuring the thermal conductivity of buildings materials, was slightly modified in order to measure the thermal conductivity of some gravel samples. The tests were performed both in dry and wet conditions. The paper presents the first obtained results.File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.