SPIDER is one of two projects of the ITER Neutral Beam Test Facility under construction in Padova, Italy, at the Consorzio RFX premises. It will have a 100 keV beam source with a full- size prototype of the radiofrequency ion source for the ITER neutral beam injector (NBI) and also, similar to the ITER diagnostic neutral beam, it is designed to operate with a pulse length of up to 3600 s, featuring an ITER-like magnetic lter eld con guration (for high extraction of negative ions) and caesium oven (for high production of negative ions) layout as well as a wide set of diagnostics. These features will allow a reproduction of the ion source operation in ITER, which cannot be done in any other existing test facility. SPIDER realization is well advanced and the rst operation is expected at the beginning of 2018, with the mission of achieving the ITER heating and diagnostic NBI ion source requirements and of improving its performance in terms of reliability and availability. This paper mainly focuses on the preparation of the rst SPIDER operations—integration and testing of SPIDER components, completion and implementation of diagnostics and control and formulation of operation and research plan, based on a staged strategy.

The ITER Neutral Beam Test Facility toward SPIDER operation

LUCHETTA, ADRIANO FRANCESCO;CHITARIN, GIUSEPPE;SERIANNI, GIANLUIGI;AGOSTINETTI, PIERO;AGOSTINI, MATTEO;APRILE, DANIELE;BALTADOR, CARLO;BARBISAN, MARCO;BROMBIN, MATTEO;DALLA PALMA, MAURO;DE MURI, MICHELA;FELLIN, FRANCESCO;GAMBETTA, GIULIO;JAIN, PALAK;MAISTRELLO, ALBERTO;MARCONATO, NICOLO';PILAN, NICOLA;PIMAZZONI, ANTONIO;RECCHIA, MAURO;SARTORI, EMANUELE;SIRAGUSA, MARCO;SPAGNOLO, SILVIA;VELTRI, PIERLUIGI;ZAMENGO, ANDREA;ZANIOL, BARBARA;ZANOTTO, LORIS;ZAUPA, MATTEO;
2017

Abstract

SPIDER is one of two projects of the ITER Neutral Beam Test Facility under construction in Padova, Italy, at the Consorzio RFX premises. It will have a 100 keV beam source with a full- size prototype of the radiofrequency ion source for the ITER neutral beam injector (NBI) and also, similar to the ITER diagnostic neutral beam, it is designed to operate with a pulse length of up to 3600 s, featuring an ITER-like magnetic lter eld con guration (for high extraction of negative ions) and caesium oven (for high production of negative ions) layout as well as a wide set of diagnostics. These features will allow a reproduction of the ion source operation in ITER, which cannot be done in any other existing test facility. SPIDER realization is well advanced and the rst operation is expected at the beginning of 2018, with the mission of achieving the ITER heating and diagnostic NBI ion source requirements and of improving its performance in terms of reliability and availability. This paper mainly focuses on the preparation of the rst SPIDER operations—integration and testing of SPIDER components, completion and implementation of diagnostics and control and formulation of operation and research plan, based on a staged strategy.
2017
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3237227
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 45
  • ???jsp.display-item.citation.isi??? 44
  • OpenAlex ND
social impact