Valid and reliable accessible measures of balance are required in a health-related fitness test battery, both in the general population and in groups with special needs. For this purpose, the capability of the Wii Balance Board (WBB) in evaluating standing balance was analysed and compared with a laboratory-graded force platform (FP). A 30-s double limb standing test with open and closed eyes was performed by 28 individuals (12 male and 16 female, mean age = 23.8, SD = +/- 2.7 years). A simple method of acquisition of the centre of pressure (CoP) over time was applied to compare WBB and FP simultaneously on the same signal. User-defined software was developed to obtain the CoP from WBB over time and the resulting related measures and graphical representations. The comparison of measures, such as sway path and maximum oscillations along the anterior-posterior and medial-lateral direction, obtained with the FP and the WBB shows that the latter, in conjunction with the user-defined developed software, can be appropriate, considering prescribed limits, and an easy-to-use tool for evaluating standing balance.

A contribution to the validation of the Wii Balance Board for the assessment of standing balance

PAVAN, PIERO;Matteo Cardaioli;FERRI, ILARIA;GOBBI, ERICA;CARRARO, ATTILIO
2015

Abstract

Valid and reliable accessible measures of balance are required in a health-related fitness test battery, both in the general population and in groups with special needs. For this purpose, the capability of the Wii Balance Board (WBB) in evaluating standing balance was analysed and compared with a laboratory-graded force platform (FP). A 30-s double limb standing test with open and closed eyes was performed by 28 individuals (12 male and 16 female, mean age = 23.8, SD = +/- 2.7 years). A simple method of acquisition of the centre of pressure (CoP) over time was applied to compare WBB and FP simultaneously on the same signal. User-defined software was developed to obtain the CoP from WBB over time and the resulting related measures and graphical representations. The comparison of measures, such as sway path and maximum oscillations along the anterior-posterior and medial-lateral direction, obtained with the FP and the WBB shows that the latter, in conjunction with the user-defined developed software, can be appropriate, considering prescribed limits, and an easy-to-use tool for evaluating standing balance.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2921299
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
  • OpenAlex ND
social impact