A new RP-HPLC method for the separation and quantification of the most common genetic variants of bovine milk proteins is described. A reversed-phase analytical column C8 (Zorbax 300SB-C8 RP, 3.5 microm, 300A, 150 x 4.6 I.D.) was used. All the most common casein (CN) and whey protein genetic variants, including beta-CN(I) were detected and separated simultaneously in less then 40 min, with the exception of alpha(S1)-CN(B) and CN(C) variants. Purified protein genetic variants were employed in calibration and showed different absorbances at 214 nm. The procedure was developed using 40 raw individual milk samples of cows belonging to four different breeds and certified skim milk powder BCR-063R. Method validation consisted in testing linearity, repeatability, reproducibility and accuracy. A linear relationship (R(2)>0.99) between the concentrations of proteins and peak areas was observed over the concentration range, with low detection limits. Repeatability and reproducibility were satisfactory for both retention times and peak areas. The RSD of peak areas ranged from 0.92 to 4.32% within analytical day and from 0.85 to 9.52% across analytical days. The recoveries, calculated using mixtures of samples previously quantified, ranged from 98.1 to 103.7%.

Validation of a new reversed-phase high-performance liquid chromatography method for separation and quantification of bovine milk protein genetic variants

BONFATTI, VALENTINA;CECCHINATO, ALESSIO;GALLO, LUIGI;CARNIER, PAOLO
2008

Abstract

A new RP-HPLC method for the separation and quantification of the most common genetic variants of bovine milk proteins is described. A reversed-phase analytical column C8 (Zorbax 300SB-C8 RP, 3.5 microm, 300A, 150 x 4.6 I.D.) was used. All the most common casein (CN) and whey protein genetic variants, including beta-CN(I) were detected and separated simultaneously in less then 40 min, with the exception of alpha(S1)-CN(B) and CN(C) variants. Purified protein genetic variants were employed in calibration and showed different absorbances at 214 nm. The procedure was developed using 40 raw individual milk samples of cows belonging to four different breeds and certified skim milk powder BCR-063R. Method validation consisted in testing linearity, repeatability, reproducibility and accuracy. A linear relationship (R(2)>0.99) between the concentrations of proteins and peak areas was observed over the concentration range, with low detection limits. Repeatability and reproducibility were satisfactory for both retention times and peak areas. The RSD of peak areas ranged from 0.92 to 4.32% within analytical day and from 0.85 to 9.52% across analytical days. The recoveries, calculated using mixtures of samples previously quantified, ranged from 98.1 to 103.7%.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2446110
Citazioni
  • ???jsp.display-item.citation.pmc??? 25
  • Scopus 175
  • ???jsp.display-item.citation.isi??? 161
social impact