This retrospective study evaluated hard and soft tissue response and reported mechanical and technical complications around computer-aided design/computer-assisted manufactured (CAD/CAM) abutments. A total of 123 patients restored with titanium, gold-hue titanium, and zirconia CAD/CAM abutments were included (N = 291). Each patient was followed up for at least 2 years. Clinical and radiographic parameters were assessed annually and complications were recorded. No implant or reconstruction failures were reported. One fracture of a zirconia abutment occurred. The prosthetic survival rate after 4 years of function for restorations and abutments was 100% and 99.66%, respectively. No significant differences in biologic and radiographic indices were found. The bleeding on probing index was positive at 42% of implant sites, and it had no significant correlation with the overall change in marginal bone level (0.02 mm) of bone gain. The short-term survival of CAD/CAM abutments was reliable, no matter of the material used for manufacturing.

CAD/CAM Implant Abutments: Peri-implant Hard and Soft Tissue Response with Up to 4 Years of Follow-up- A Retrospective Cohort Study Evaluation

Cecchinato, Denis;Bressan, Eriberto;Lops, Diego
2020

Abstract

This retrospective study evaluated hard and soft tissue response and reported mechanical and technical complications around computer-aided design/computer-assisted manufactured (CAD/CAM) abutments. A total of 123 patients restored with titanium, gold-hue titanium, and zirconia CAD/CAM abutments were included (N = 291). Each patient was followed up for at least 2 years. Clinical and radiographic parameters were assessed annually and complications were recorded. No implant or reconstruction failures were reported. One fracture of a zirconia abutment occurred. The prosthetic survival rate after 4 years of function for restorations and abutments was 100% and 99.66%, respectively. No significant differences in biologic and radiographic indices were found. The bleeding on probing index was positive at 42% of implant sites, and it had no significant correlation with the overall change in marginal bone level (0.02 mm) of bone gain. The short-term survival of CAD/CAM abutments was reliable, no matter of the material used for manufacturing.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3543258
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
  • OpenAlex ND
social impact