In Europe, many archeological sites require continuous maintenance interventions capable of preserving the cultural value of this type of heritage. To this end, particular attention must be paid to ruins, the remains of larger portions and archeological artifacts. These elements, generally made of ancient stone masonry materials are vulnerable to external action such as are earthquakes, differential settlements, degradation, etc.. In order to reduce their structural vulnerability, repair interventions are usually required using repair techniques that preserve the artistic and aesthetical values of the archeological element. One of these techniques is the use of external post-tensioning system through pre-stressed cables.In this contribution, some examples of the application of post-tensioning to an archeological element are presented. The application of rigid-block analysis to archeological elements (retrofitted with external post-tensioning system) is developed and discussed. (C) 2020 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/) Peer-review under responsibility of Marco Tanganelli and Stefania Viti

Rigid-block analysis of archeological elements retrofitted with external post-tensioning system

Zampieri, P
;
Pellegrino, C
2020

Abstract

In Europe, many archeological sites require continuous maintenance interventions capable of preserving the cultural value of this type of heritage. To this end, particular attention must be paid to ruins, the remains of larger portions and archeological artifacts. These elements, generally made of ancient stone masonry materials are vulnerable to external action such as are earthquakes, differential settlements, degradation, etc.. In order to reduce their structural vulnerability, repair interventions are usually required using repair techniques that preserve the artistic and aesthetical values of the archeological element. One of these techniques is the use of external post-tensioning system through pre-stressed cables.In this contribution, some examples of the application of post-tensioning to an archeological element are presented. The application of rigid-block analysis to archeological elements (retrofitted with external post-tensioning system) is developed and discussed. (C) 2020 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/) Peer-review under responsibility of Marco Tanganelli and Stefania Viti
2020
Procedia Structural Integrity
Volume 29, Pages 192 - 1982020 1st International Conference on Art Collections ARCO 2020Florence28 May 2020through 30 May 2020
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3480857
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
  • OpenAlex ND
social impact