: Forms of noninvasive respiratory support (NIRS) have been widely used to avoid endotracheal intubation in patients with coronavirus disease-19 (COVID-19). However, inappropriate prolongation of NIRS may delay endotracheal intubation and worsen patient outcomes. The aim of this retrospective study was to assess whether the CARE score, a chest X-ray score previously validated in COVID-19 patients, may predict the need for endotracheal intubation and escalation of respiratory support in COVID-19 patients requiring NIRS. From December 2020 to May 2021, we included 142 patients receiving NIRS who had a first chest X-ray available at NIRS initiation and a second one after 48-72 h. In 94 (66%) patients, the level of respiratory support was increased, while endotracheal intubation was required in 83 (58%) patients. The CARE score at NIRS initiation was not predictive of the need for endotracheal intubation (odds ratio (OR) 1.01, 95% confidence interval (CI) 0.96-1.06) or escalation of treatment (OR 1.01, 95% CI 0.96-1.07). In conclusion, chest X-ray severity, as assessed by the CARE score, did not allow predicting endotracheal intubation or escalation of respiratory support in COVID-19 patients undergoing NIRS.
Chest X-ray Does Not Predict the Risk of Endotracheal Intubation and Escalation of Treatment in COVID-19 Patients Requiring Noninvasive Respiratory Support
Giraudo, Chiara;Fichera, Giulia;Della Paolera, Michele;Tocco, Martina;Gorgi, Davide;Carlucci, Silvia;Lionello, Federico;De Cassai, Alessandro;Rossato, Marco;Vianello, Andrea;Vettor, Roberto;Navalesi, Paolo;
2022
Abstract
: Forms of noninvasive respiratory support (NIRS) have been widely used to avoid endotracheal intubation in patients with coronavirus disease-19 (COVID-19). However, inappropriate prolongation of NIRS may delay endotracheal intubation and worsen patient outcomes. The aim of this retrospective study was to assess whether the CARE score, a chest X-ray score previously validated in COVID-19 patients, may predict the need for endotracheal intubation and escalation of respiratory support in COVID-19 patients requiring NIRS. From December 2020 to May 2021, we included 142 patients receiving NIRS who had a first chest X-ray available at NIRS initiation and a second one after 48-72 h. In 94 (66%) patients, the level of respiratory support was increased, while endotracheal intubation was required in 83 (58%) patients. The CARE score at NIRS initiation was not predictive of the need for endotracheal intubation (odds ratio (OR) 1.01, 95% confidence interval (CI) 0.96-1.06) or escalation of treatment (OR 1.01, 95% CI 0.96-1.07). In conclusion, chest X-ray severity, as assessed by the CARE score, did not allow predicting endotracheal intubation or escalation of respiratory support in COVID-19 patients undergoing NIRS.File | Dimensione | Formato | |
---|---|---|---|
Pettenuzzo_jcm-11-01636.pdf
accesso aperto
Tipologia:
Published (publisher's version)
Licenza:
Creative commons
Dimensione
835.4 kB
Formato
Adobe PDF
|
835.4 kB | Adobe PDF | Visualizza/Apri |