Tracheal suctioning in non-vigorous newborn delivered through meconium-stained amniotic fluid (MSAF) is supposed to delay initiation of positive pressure ventilation (PPV), but the magnitude of such delay is unknown. To compare the time of PPV initiation when performing immediate laryngoscopy with intubation and suctioning vs. performing immediate PPV without intubation in a manikin model. Randomized controlled crossover (AB/BA) trial comparing PPV initiation with or without endotracheal suctioning in a manikin model of non-vigorous neonates born through MSAF. Participants were 20 neonatologists and 20 pediatric residents trained in advanced airway management. Timing of PPV initiation was longer with vs. without endotracheal suctioning in both pediatric residents (mean difference 13 s, 95% confidence interval 8 to 18 s; p < 0.0001) and neonatologists (mean difference 12 s, 95% confidence interval 8 to 16 s; p < 0.0001). The difference in timing of PPV initiation was similar between pediatric residents and neonatologists (mean difference − 1 s, 95% confidence interval − 7 to 6 s; p = 0.85). Conclusions: Performing immediate laryngoscopy with intubation and suctioning was associated with longer—but not clinically relevant—time of initiation of PPV compared with immediate PPV without intubation in a manikin model. While suggesting negligible delay in starting PPV, further studies in a clinical setting are warranted. Registration: clinicaltrial.gov NCT04076189.What is Known:• Management of the non-vigorous newborn delivered through meconium-stained amniotic fluid remains still controversial.• Tracheal suctioning in non-vigorous newborn delivered through meconium-stained amniotic fluid is supposed to delay initiation of positive pressure ventilation, but the magnitude of such delay is unknown.What is New:• Performing immediate ventilation without intubation was associated with shorter—but not clinically relevant—time of initiation of ventilation compared to immediate laryngoscopy with intubation and suctioning in a manikin model.• Further studies in a clinical setting are warranted.

Time needed to intubate and suction a manikin prior to instituting positive pressure ventilation: a simulation trial

Cavallin F.;Res G.;Doglioni N.;Trevisanuto D.
2021

Abstract

Tracheal suctioning in non-vigorous newborn delivered through meconium-stained amniotic fluid (MSAF) is supposed to delay initiation of positive pressure ventilation (PPV), but the magnitude of such delay is unknown. To compare the time of PPV initiation when performing immediate laryngoscopy with intubation and suctioning vs. performing immediate PPV without intubation in a manikin model. Randomized controlled crossover (AB/BA) trial comparing PPV initiation with or without endotracheal suctioning in a manikin model of non-vigorous neonates born through MSAF. Participants were 20 neonatologists and 20 pediatric residents trained in advanced airway management. Timing of PPV initiation was longer with vs. without endotracheal suctioning in both pediatric residents (mean difference 13 s, 95% confidence interval 8 to 18 s; p < 0.0001) and neonatologists (mean difference 12 s, 95% confidence interval 8 to 16 s; p < 0.0001). The difference in timing of PPV initiation was similar between pediatric residents and neonatologists (mean difference − 1 s, 95% confidence interval − 7 to 6 s; p = 0.85). Conclusions: Performing immediate laryngoscopy with intubation and suctioning was associated with longer—but not clinically relevant—time of initiation of PPV compared with immediate PPV without intubation in a manikin model. While suggesting negligible delay in starting PPV, further studies in a clinical setting are warranted. Registration: clinicaltrial.gov NCT04076189.What is Known:• Management of the non-vigorous newborn delivered through meconium-stained amniotic fluid remains still controversial.• Tracheal suctioning in non-vigorous newborn delivered through meconium-stained amniotic fluid is supposed to delay initiation of positive pressure ventilation, but the magnitude of such delay is unknown.What is New:• Performing immediate ventilation without intubation was associated with shorter—but not clinically relevant—time of initiation of ventilation compared to immediate laryngoscopy with intubation and suctioning in a manikin model.• Further studies in a clinical setting are warranted.
File in questo prodotto:
File Dimensione Formato  
Cavallin2021_Article_TimeNeededToIntubateAndSuction.pdf

accesso aperto

Descrizione: Open access funding provided by Universita` degli Studi di Padova within the CRUI-CARE Agreement
Tipologia: Published (publisher's version)
Licenza: Creative commons
Dimensione 386.35 kB
Formato Adobe PDF
386.35 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3369523
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact