Introduction: The covered endovascular reconstruction of the aortic bifurcation (CERAB) represents a promising technique for the treatment obstructive lesions involving the aortic bifurcation. The aim of this report is to describe the use of a new generation balloon-expandable stent-graft (Viabahn VBX, W.L. Gore&Associates, AZ, USA), in the CERAB configuration for the treatment of aorto-iliac obstructive lesions involving the infrarenal aorta and bifurcation. Technical note: This technique was adopted in two patients with severe aorto-iliac obstructive lesions. After bilateral iliac recanalization, an 11 mm diameter VBX stent was deployed in the infrarenal aorta; a post-dilatation up to 16 mm with a non-compliant balloon was performed to adapt the proximal edge of the stent to the aortic diameter. Two 8 mm diameter VBX stents were then deployed at the aortic bifurcation in a kissing conformation, overlapping with the previously positioned aortic stent for 15 mm. A post-ballooning with two kissing 12 × 20 mm compliant balloons (Powerflex Pro PTA, Cordis, CA, USA) was performed to adapt the parallel stents to the aortic cuff. A post-operative angio-CT demonstrated optimal conformability of the aortic cuff to the aortic wall, and apposition of the kissing stents to the aortic cuff. Conclusions: This preliminary experience shows that the VBX stent may allow an effective reconstruction of the aortic bifurcation; the conformability and flaring capability may allow to overcome the diameter mismatch between the aorta and the iliac arteries.

The Viabahn balloon expandable stent for endovascular reconstruction of the infrarenal aorta and its bifurcation in cases of severe obstructive disease

Antonello M.;Squizzato F.;Piazza M.
2020

Abstract

Introduction: The covered endovascular reconstruction of the aortic bifurcation (CERAB) represents a promising technique for the treatment obstructive lesions involving the aortic bifurcation. The aim of this report is to describe the use of a new generation balloon-expandable stent-graft (Viabahn VBX, W.L. Gore&Associates, AZ, USA), in the CERAB configuration for the treatment of aorto-iliac obstructive lesions involving the infrarenal aorta and bifurcation. Technical note: This technique was adopted in two patients with severe aorto-iliac obstructive lesions. After bilateral iliac recanalization, an 11 mm diameter VBX stent was deployed in the infrarenal aorta; a post-dilatation up to 16 mm with a non-compliant balloon was performed to adapt the proximal edge of the stent to the aortic diameter. Two 8 mm diameter VBX stents were then deployed at the aortic bifurcation in a kissing conformation, overlapping with the previously positioned aortic stent for 15 mm. A post-ballooning with two kissing 12 × 20 mm compliant balloons (Powerflex Pro PTA, Cordis, CA, USA) was performed to adapt the parallel stents to the aortic cuff. A post-operative angio-CT demonstrated optimal conformability of the aortic cuff to the aortic wall, and apposition of the kissing stents to the aortic cuff. Conclusions: This preliminary experience shows that the VBX stent may allow an effective reconstruction of the aortic bifurcation; the conformability and flaring capability may allow to overcome the diameter mismatch between the aorta and the iliac arteries.
2020
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3366335
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
  • OpenAlex ND
social impact