The authors describe the transapical deployment of a thoracic endograft to exclude a saphenous vein graft proximal anastomotic pseudoaneurysm following coronary artery bypass grafting (CABG) in a 63-year-old male with a prosthetic aortic valve. A standard thoracic endograft has been deployed via transapical access after percutaneous transluminal coronary angioplasty of the native vessel perfused by the patent CABG. The procedure was uneventful; an 8-month computed tomography scan showed complete exclusion of the pseudoaneurysm with patency of supra-aortic trunks.
Transapical Deployment of Thoracic Stent Graft for Ascending Aorta Coronary Bypass Pseudoaneurysm in a Patient with Prosthetic Aortic Valve
Antonello, Michele;D'Onofrio, Augusto;Zavatta, Marco;Maturi, Carlo;Piazza, Michele;Gerosa, Gino
2019
Abstract
The authors describe the transapical deployment of a thoracic endograft to exclude a saphenous vein graft proximal anastomotic pseudoaneurysm following coronary artery bypass grafting (CABG) in a 63-year-old male with a prosthetic aortic valve. A standard thoracic endograft has been deployed via transapical access after percutaneous transluminal coronary angioplasty of the native vessel perfused by the patent CABG. The procedure was uneventful; an 8-month computed tomography scan showed complete exclusion of the pseudoaneurysm with patency of supra-aortic trunks.File in questo prodotto: