Unusual inflow sources and device introduction sites in aortic arch debranching. Deriu G, Grego F, Frigatti P, Gerosa G, Piazza M, Bonvini S, Maturi C, Antonello M, Menegolo M. Source Department of Cardiac, Thoracic and Vascular Sciences, Vascular and Endovascular Surgery, University of Padua, Padua, Italy. Abstract AIM: Aim of the study was to evaluate a single center experience on hybrid treatment for thoracic aortic diseases, including aortic arch and ascending aorta endografting needing a total debranching from descending thoracic aorta and an antegrade endograft deployment from left ventricle. METHODS: Between January 2004 and December 2010 48 patients underwent thoracic aorta endografting, with coverage of at least one supra-aortic artery, because of atherosclerotic, dissecting and post-traumatic aneurysms or complications of previous aortic surgery. Supra-aortic trunks revascularization was obtained from ascending aorta, common carotid arteries and, in three cases, from descending thoracic aorta since the unavailability of common inflow sites. In three cases the antegrade endograft introduction through left ventricle (transapical approach, 2 cases) or ascending aorta (one case) was the only possibility for a safe deployment. RESULTS: Three groups have been identified on the basis of the proximal landing zone. Group A (27 patients): zone 2; Group B (9 patients): zone 1; Group C (12 patients): zone 0. The 30 days mortality was respectively 7.4%, 0% and 16%. Post operative paraplegia occurred in the 7.4% of group A, respiratory insufficiency and infections were the main post-operative complications with an incidence reaching 30% in each group. CONCLUSION: Hybrid procedures on aortic arch represent a possible treatment for cases unfit for open surgery despite the complication rates and mortality are not negligible. In selected cases, the endografting can be extended up to beyond the landing zone 0 where an antegrade transventricular endograft deployment and a supra-aortic perfusion from descending thoracic aorta represent a feasible option.

Unusual inflow sources and device introduction sites in aortic arch debranching.

DERIU, GIOVANNI PAOLO;GREGO, FRANCO;GEROSA, GINO;PIAZZA, MICHELE;BONVINI, STEFANO;MATURI, CARLO;ANTONELLO, MICHELE;MENEGOLO, MIRKO
2012

Abstract

Unusual inflow sources and device introduction sites in aortic arch debranching. Deriu G, Grego F, Frigatti P, Gerosa G, Piazza M, Bonvini S, Maturi C, Antonello M, Menegolo M. Source Department of Cardiac, Thoracic and Vascular Sciences, Vascular and Endovascular Surgery, University of Padua, Padua, Italy. Abstract AIM: Aim of the study was to evaluate a single center experience on hybrid treatment for thoracic aortic diseases, including aortic arch and ascending aorta endografting needing a total debranching from descending thoracic aorta and an antegrade endograft deployment from left ventricle. METHODS: Between January 2004 and December 2010 48 patients underwent thoracic aorta endografting, with coverage of at least one supra-aortic artery, because of atherosclerotic, dissecting and post-traumatic aneurysms or complications of previous aortic surgery. Supra-aortic trunks revascularization was obtained from ascending aorta, common carotid arteries and, in three cases, from descending thoracic aorta since the unavailability of common inflow sites. In three cases the antegrade endograft introduction through left ventricle (transapical approach, 2 cases) or ascending aorta (one case) was the only possibility for a safe deployment. RESULTS: Three groups have been identified on the basis of the proximal landing zone. Group A (27 patients): zone 2; Group B (9 patients): zone 1; Group C (12 patients): zone 0. The 30 days mortality was respectively 7.4%, 0% and 16%. Post operative paraplegia occurred in the 7.4% of group A, respiratory insufficiency and infections were the main post-operative complications with an incidence reaching 30% in each group. CONCLUSION: Hybrid procedures on aortic arch represent a possible treatment for cases unfit for open surgery despite the complication rates and mortality are not negligible. In selected cases, the endografting can be extended up to beyond the landing zone 0 where an antegrade transventricular endograft deployment and a supra-aortic perfusion from descending thoracic aorta represent a feasible option.
2012
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2514775
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
  • OpenAlex ND
social impact