This paper describes a set of experimental tests on a dual three-phase induction machine for fault-tolerant applications. Both three-phase and six-phase machine operations are considered. Different winding configurations are investigated and compared in case of both open-circuit and short-circuit faults. Experimental tests for each configuration are reported at no-load and under load operating conditions.

Experimental Tests of Dual Three-Phase Induction Motor Under Faulty Operating Condition

ALBERTI, LUIGI;BIANCHI, NICOLA
2012

Abstract

This paper describes a set of experimental tests on a dual three-phase induction machine for fault-tolerant applications. Both three-phase and six-phase machine operations are considered. Different winding configurations are investigated and compared in case of both open-circuit and short-circuit faults. Experimental tests for each configuration are reported at no-load and under load operating conditions.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2514424