This paper discusses and analyses the parallel operation of uninterruptible power supplies (UPS) when loaded through long wiring cables having non-negligible inductance and resistance. This scenario is often encountered in practice, as the UPS power supplies are often located far from each other and from the load they are actually powering. The analysis demonstrates how long cable connections between the power supply system and the load deeply modify the behavior of the single UPS unit. It is shown how the cable inductance interacts with the UPS closed-loop output impedance modifying the control loop gain, ultimately generating resonance phenomena, which deteriorate or even compromise system stability and performances, if suitable provisions are not taken at the design stage. Experimental results carried out on two paralleled three phase, 40 kVA UPS units based on voltage-source inverters topologies confirm the validity of the theoretical discussion and the practical relevance of the phenomenon.

Analysis of Parallel Operation of Uninterruptible Power Supplies Loaded through Long Wiring Cables

CORRADINI, LUCA;MATTAVELLI, PAOLO;
2010

Abstract

This paper discusses and analyses the parallel operation of uninterruptible power supplies (UPS) when loaded through long wiring cables having non-negligible inductance and resistance. This scenario is often encountered in practice, as the UPS power supplies are often located far from each other and from the load they are actually powering. The analysis demonstrates how long cable connections between the power supply system and the load deeply modify the behavior of the single UPS unit. It is shown how the cable inductance interacts with the UPS closed-loop output impedance modifying the control loop gain, ultimately generating resonance phenomena, which deteriorate or even compromise system stability and performances, if suitable provisions are not taken at the design stage. Experimental results carried out on two paralleled three phase, 40 kVA UPS units based on voltage-source inverters topologies confirm the validity of the theoretical discussion and the practical relevance of the phenomenon.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2433061
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 61
  • ???jsp.display-item.citation.isi??? 47
social impact