Minerals and trace elements are vital for numerous physiological processes in mammals. The current reference analysis for mineral determination in biological matrices is inductively coupled plasma mass spectrometry (ICP-MS). This analysis is costly, time consuming, and destructive. While commercial kits are a viable alternative to ICP-MS due to the lower cost, their limit lies in the ability of determining only one mineral at a time. Energy-dispersive X-ray fluorescence (ED-XRF) has been proposed as a potential alternative for the rapid determination of mineral concentration in biological matrices. This study evaluated the accuracy of ED-XRF as an alternative to commercial diagnostic kits to predict the concentrations of sodium, magnesium, phosphorus, chloride, potassium, calcium, iron, and selenium in cattle plasma without sample pretreatment, potentially reducing the time of analysis compared to commercial kits and costs and labor compared to ICP-MS. Reference mineral concentrations were determined in 277 samples using in vitro diagnostics regulation-certified commercial diagnostic kits. The results indicated a moderate prediction accuracy only for potassium. For the other minerals, the prediction accuracy of ED-XRF was insufficient, which suggests that some degree of sample preparation is necessary to improve the determination of minerals in plasma.
The Role of Energy-Dispersive X-Ray Fluorescence to Predict Mineral Content in Untreated Bovine Plasma
Martini, Davide;Magro, Silvia
;Pozza, Marta;Penasa, Mauro;De Marchi, Massimo
2025
Abstract
Minerals and trace elements are vital for numerous physiological processes in mammals. The current reference analysis for mineral determination in biological matrices is inductively coupled plasma mass spectrometry (ICP-MS). This analysis is costly, time consuming, and destructive. While commercial kits are a viable alternative to ICP-MS due to the lower cost, their limit lies in the ability of determining only one mineral at a time. Energy-dispersive X-ray fluorescence (ED-XRF) has been proposed as a potential alternative for the rapid determination of mineral concentration in biological matrices. This study evaluated the accuracy of ED-XRF as an alternative to commercial diagnostic kits to predict the concentrations of sodium, magnesium, phosphorus, chloride, potassium, calcium, iron, and selenium in cattle plasma without sample pretreatment, potentially reducing the time of analysis compared to commercial kits and costs and labor compared to ICP-MS. Reference mineral concentrations were determined in 277 samples using in vitro diagnostics regulation-certified commercial diagnostic kits. The results indicated a moderate prediction accuracy only for potassium. For the other minerals, the prediction accuracy of ED-XRF was insufficient, which suggests that some degree of sample preparation is necessary to improve the determination of minerals in plasma.File | Dimensione | Formato | |
---|---|---|---|
animals-15-01133-v2.pdf
accesso aperto
Tipologia:
Published (Publisher's Version of Record)
Licenza:
Creative commons
Dimensione
1.45 MB
Formato
Adobe PDF
|
1.45 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate