Purpose: To report the long-term anatomical and functional results of macular buckle for Myopic Traction Maculopathy (MTM) in stages 3a, 3b, 4a, and 4b according to the MTM Staging System (MSS). Methods: Retrospective observational cohort study involving 55 consecutive patients with MTM in stages 3a, 3b, 4a, and 4b who underwent macular buckle (MB). Postoperative outcomes, including optical coherence tomography (OCT) scans to evaluate the MTM stage and its progression, were evaluated 1-month postoperatively (i.e., “intermediate follow-up”) and at last follow-up ranging between 6 and 156 months postoperatively (i.e., “final follow-up”). Results: Fifty-five eyes affected by MTM who underwent MB were enrolled. The mean preoperative and postoperative axial length was 31.13 ± 2.14 and 29.73 ± 2.16 mm, respectively (p < 0.01), with a mean axial shift of 1.32 ± 0.77 mm. The mean sample best corrected visual acuity (BCVA) at baseline, intermediate, and final follow-ups was 0.87 ± 0.36, 0.73 ± ...

Long-Term results of macular buckle for MTM stage 3-4 With maculoschisis and macular detachment without and With lamellar macular hole

Lorenzo Motta;
2024

Abstract

Purpose: To report the long-term anatomical and functional results of macular buckle for Myopic Traction Maculopathy (MTM) in stages 3a, 3b, 4a, and 4b according to the MTM Staging System (MSS). Methods: Retrospective observational cohort study involving 55 consecutive patients with MTM in stages 3a, 3b, 4a, and 4b who underwent macular buckle (MB). Postoperative outcomes, including optical coherence tomography (OCT) scans to evaluate the MTM stage and its progression, were evaluated 1-month postoperatively (i.e., “intermediate follow-up”) and at last follow-up ranging between 6 and 156 months postoperatively (i.e., “final follow-up”). Results: Fifty-five eyes affected by MTM who underwent MB were enrolled. The mean preoperative and postoperative axial length was 31.13 ± 2.14 and 29.73 ± 2.16 mm, respectively (p < 0.01), with a mean axial shift of 1.32 ± 0.77 mm. The mean sample best corrected visual acuity (BCVA) at baseline, intermediate, and final follow-ups was 0.87 ± 0.36, 0.73 ± ...
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3545491
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
  • OpenAlex ND
social impact