Transcatheter aortic valve replacement (TAVR) has become more common than surgical aortic valve replacement since 2016, with over 200,000 procedures globally each year. As patients increasingly outlive their TAVR devices, managing these cases is a growing concern. Treatment options include surgical removal of the old TAVR device (transcatheter aortic valve [TAV] explant) or implantation of a new transcatheter aortic valve (redo TAV). Redo TAV is complex because of the unique designs of TAV devices; compatibility issues; and the need for individualized planning based on factors such as implant depth, shape, and coronary artery relationships. This review serves as a comprehensive guide for redo TAV, detailing the design characteristics of TAV devices, device compatibility, standardized terminology, and a structured approach for computed tomography analysis. It aims to facilitate decision making, risk identification, and achieving optimal outcomes in redo TAV procedures. (JACC Cardiovasc Interv 2024;17:1631-1651) (c) 2024 by the American College of Cardiology Foundation.

A Guide to Transcatheter Aortic Valve Design and Systematic Planning for a Redo-TAV (TAV-in-TAV) Procedure

Tarantini, Giuseppe;
2024

Abstract

Transcatheter aortic valve replacement (TAVR) has become more common than surgical aortic valve replacement since 2016, with over 200,000 procedures globally each year. As patients increasingly outlive their TAVR devices, managing these cases is a growing concern. Treatment options include surgical removal of the old TAVR device (transcatheter aortic valve [TAV] explant) or implantation of a new transcatheter aortic valve (redo TAV). Redo TAV is complex because of the unique designs of TAV devices; compatibility issues; and the need for individualized planning based on factors such as implant depth, shape, and coronary artery relationships. This review serves as a comprehensive guide for redo TAV, detailing the design characteristics of TAV devices, device compatibility, standardized terminology, and a structured approach for computed tomography analysis. It aims to facilitate decision making, risk identification, and achieving optimal outcomes in redo TAV procedures. (JACC Cardiovasc Interv 2024;17:1631-1651) (c) 2024 by the American College of Cardiology Foundation.
2024
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3530457
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 16
  • OpenAlex ND
social impact