The aim of this work is a technical review about Quartz Crystal Microbalance (QCM) sensors used in space missions, i.e. Space Shuttle flights, i.e. NASA Space Transportation System (NASA STS) and satellite missions, that aimed at monitoring the contamination generated by outgassing processes of materials onboard satellites and sensitive payloads. The contamination processes are critical for scientific instrumentation (e.g. optics, telescopes, detectors) because scientific measurements and performances can be jeopardized or worsened by uncontrolled contamination. This issue has been addressed by the space agencies, e.g. NASA, ESA and JAXA that have implemented many different studies to monitor the material outgassing and degradation in space environment. During the past years, the QCM sensors have become the baseline solution for measuring material outgassing and characterizing the on-orbit contamination environment. This work summarizes the main QCM applications in Space and their findings, providing an overview of the sensors’ performances in terms of stability, power, data rate, measurement accuracy and resolution. Different QCM technologies will be compared highlighting the advantages of their use for the next space missions and instrumentations that require an accurate monitoring of contamination environment. In particular, due to more severe contamination requirements for next payloads and instrumentations, QCM sensors would be useful to estimate the cleanliness degree by evaluating the induced contamination and degradation on sensitive instrumentations.

A review of quartz crystal microbalances for space applications

Saggin B.;
2019

Abstract

The aim of this work is a technical review about Quartz Crystal Microbalance (QCM) sensors used in space missions, i.e. Space Shuttle flights, i.e. NASA Space Transportation System (NASA STS) and satellite missions, that aimed at monitoring the contamination generated by outgassing processes of materials onboard satellites and sensitive payloads. The contamination processes are critical for scientific instrumentation (e.g. optics, telescopes, detectors) because scientific measurements and performances can be jeopardized or worsened by uncontrolled contamination. This issue has been addressed by the space agencies, e.g. NASA, ESA and JAXA that have implemented many different studies to monitor the material outgassing and degradation in space environment. During the past years, the QCM sensors have become the baseline solution for measuring material outgassing and characterizing the on-orbit contamination environment. This work summarizes the main QCM applications in Space and their findings, providing an overview of the sensors’ performances in terms of stability, power, data rate, measurement accuracy and resolution. Different QCM technologies will be compared highlighting the advantages of their use for the next space missions and instrumentations that require an accurate monitoring of contamination environment. In particular, due to more severe contamination requirements for next payloads and instrumentations, QCM sensors would be useful to estimate the cleanliness degree by evaluating the induced contamination and degradation on sensitive instrumentations.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3523445
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 48
  • ???jsp.display-item.citation.isi??? 43
  • OpenAlex ND
social impact