The Pump-As-Turbine ( PAT ) technology has become popular in micro hydropower stations due to its simple installation and cost-effectiveness. Nevertheless, power failures present a substantial risk to the secure and steady functioning of PAT 's braking system. The commercial CFD code ( ANSYSCFX ) is improved by incorporating a secondary development to model the power-off transition using Fortran accurately. This enhancement allows for real-time iterative calculations of angular momentum equations for mixed-flow PAT at different speeds. Meanwhile, the time-frequency domain analysis is utilized to analyze pressure pulsation signals and the evolution of the internal flow field in mixed-flow PAT. . An investigation was conducted to have a deeper understanding of braking circumstances. The results revealed that the main frequency of the pressure pulsation aligns with the blade frequency at various flow rates, and there is a sudden change in pressure amplitude during the braking phase. The impeller experienced the majority of energy losses, with the draft tube being the subsequent area of concern. In addition, a thorough examination and comparison of the changes in the internal flow field during braking were carried out. This analysis revealed a distinct double helix structure within the draft tube, with a slower inner helix and a faster outer helix. Furthermore, it was observed that there is a strong correlation between wall shear stresses and hydraulic losses on the blade surface. This research enhanced understanding of the flow characteristics of mixed-flow PAT can help improve system safety and provide valuable guidance for future optimization efforts.

Research on the mechanism of severe unsteadiness of PAT braking condition during the power failure

Pavesi G.
;
2024

Abstract

The Pump-As-Turbine ( PAT ) technology has become popular in micro hydropower stations due to its simple installation and cost-effectiveness. Nevertheless, power failures present a substantial risk to the secure and steady functioning of PAT 's braking system. The commercial CFD code ( ANSYSCFX ) is improved by incorporating a secondary development to model the power-off transition using Fortran accurately. This enhancement allows for real-time iterative calculations of angular momentum equations for mixed-flow PAT at different speeds. Meanwhile, the time-frequency domain analysis is utilized to analyze pressure pulsation signals and the evolution of the internal flow field in mixed-flow PAT. . An investigation was conducted to have a deeper understanding of braking circumstances. The results revealed that the main frequency of the pressure pulsation aligns with the blade frequency at various flow rates, and there is a sudden change in pressure amplitude during the braking phase. The impeller experienced the majority of energy losses, with the draft tube being the subsequent area of concern. In addition, a thorough examination and comparison of the changes in the internal flow field during braking were carried out. This analysis revealed a distinct double helix structure within the draft tube, with a slower inner helix and a faster outer helix. Furthermore, it was observed that there is a strong correlation between wall shear stresses and hydraulic losses on the blade surface. This research enhanced understanding of the flow characteristics of mixed-flow PAT can help improve system safety and provide valuable guidance for future optimization efforts.
2024
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3522583
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
  • OpenAlex ND
social impact