Background: This study aimed to investigate the characteristics and outcomes of patients diagnosed with Brugada syndrome (BrS) who underwent implantable loop recorder (ILR) insertion during routine clinical activity. Methods: We conducted a comprehensive screening of all consecutive patients diagnosed with BrS at our institution. We analyzed baseline clinical characteristics, arrhythmic findings, and outcomes. Results: Out of 147 BrS patients, 42 (29 %) received an ILR, 13 (9 %) underwent implantable cardioverter-defibrillator (ICD) placement, and 92 patients (63 %) continued regular cardiological follow-up. Patients who received an ILR had a higher prevalence of suspected arrhythmic syncope (43 % vs. 22 %, p = 0.012) and tended to be younger (median age 38 years, interquartile range 30–52, vs. 43 years, 35–55, p = 0.044) with a higher presence of SCN5A gene mutations (17 % vs. 6 %, p = 0.066) compared to those who continued regular follow-up. Additionally, compared to patients with an ICD, those with an ILR had a significantly lower frequency of positive programmed ventricular stimulation (0 % vs. 91 %, p < 0.001). During a median follow-up period of 14.7 months (4.7–44.8), no deaths occurred among the patients with ILR. Eight individuals (19 %) were diagnosed with arrhythmic findings through continuous ILR monitoring, primarily atrial fibrillation, and asystolic pauses. The median time from insertion to the occurrence of these events was 8.7 months (3.6–46.4). No adverse events related to ILR were reported. Conclusion: Continuous monitoring with ILR may facilitate the timely detection of non-malignant rhythm disorders in BrS patients with risk factors but without an indication for primary prevention ICD implantation.

Implantable loop recorder in Brugada syndrome: Insights from a single-center experience

Giacopelli D.;
2024

Abstract

Background: This study aimed to investigate the characteristics and outcomes of patients diagnosed with Brugada syndrome (BrS) who underwent implantable loop recorder (ILR) insertion during routine clinical activity. Methods: We conducted a comprehensive screening of all consecutive patients diagnosed with BrS at our institution. We analyzed baseline clinical characteristics, arrhythmic findings, and outcomes. Results: Out of 147 BrS patients, 42 (29 %) received an ILR, 13 (9 %) underwent implantable cardioverter-defibrillator (ICD) placement, and 92 patients (63 %) continued regular cardiological follow-up. Patients who received an ILR had a higher prevalence of suspected arrhythmic syncope (43 % vs. 22 %, p = 0.012) and tended to be younger (median age 38 years, interquartile range 30–52, vs. 43 years, 35–55, p = 0.044) with a higher presence of SCN5A gene mutations (17 % vs. 6 %, p = 0.066) compared to those who continued regular follow-up. Additionally, compared to patients with an ICD, those with an ILR had a significantly lower frequency of positive programmed ventricular stimulation (0 % vs. 91 %, p < 0.001). During a median follow-up period of 14.7 months (4.7–44.8), no deaths occurred among the patients with ILR. Eight individuals (19 %) were diagnosed with arrhythmic findings through continuous ILR monitoring, primarily atrial fibrillation, and asystolic pauses. The median time from insertion to the occurrence of these events was 8.7 months (3.6–46.4). No adverse events related to ILR were reported. Conclusion: Continuous monitoring with ILR may facilitate the timely detection of non-malignant rhythm disorders in BrS patients with risk factors but without an indication for primary prevention ICD implantation.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S235290672400037X-main.pdf

accesso aperto

Tipologia: Published (Publisher's Version of Record)
Licenza: Creative commons
Dimensione 2.73 MB
Formato Adobe PDF
2.73 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3522050
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
  • OpenAlex ND
social impact