This work describes a method to inject light into tapered optical fibers (TFs) in order to achieve site-selective and wide-volume optical control of neural activity with a single optical setup. The method relies on a Galvanometric - Resonant mirrors scan head, employed to inject light into the fiber to: (i) select a specific subset of guided modes obtaining localized illumination or (ii) to scan between the different guided modes at high-rate to obtain full NA-like light injection on time scales >0.2 ms. This is shown by analysing the light emission profiles from the TF with different voltage biases applied to the Galvanometric and the Resonant mirrors, and comparing them with a standard Full NA light-injection. With the aim to find the experimental parameters to obtain efficient Full NA - like emission profile, the Emission Length and the First Emission Diameter of TFs were extracted and compared with an ideal wide-volume emitter. Both Galvanometric and Resonant scanners methods shown a good agreement with the reference values of the standard Full NA injection, allowing neuroscientists to switch from site-selective to wide-volume illumination using a single optical setup.

Tapered fibers for optogenetics: Gaining spatial resolution in deep brain regions by exploiting angle-selective light injection systems

Pisano F.;
2019

Abstract

This work describes a method to inject light into tapered optical fibers (TFs) in order to achieve site-selective and wide-volume optical control of neural activity with a single optical setup. The method relies on a Galvanometric - Resonant mirrors scan head, employed to inject light into the fiber to: (i) select a specific subset of guided modes obtaining localized illumination or (ii) to scan between the different guided modes at high-rate to obtain full NA-like light injection on time scales >0.2 ms. This is shown by analysing the light emission profiles from the TF with different voltage biases applied to the Galvanometric and the Resonant mirrors, and comparing them with a standard Full NA light-injection. With the aim to find the experimental parameters to obtain efficient Full NA - like emission profile, the Emission Length and the First Emission Diameter of TFs were extracted and compared with an ideal wide-volume emitter. Both Galvanometric and Resonant scanners methods shown a good agreement with the reference values of the standard Full NA injection, allowing neuroscientists to switch from site-selective to wide-volume illumination using a single optical setup.
2019
International Conference on Transparent Optical Networks
21st International Conference on Transparent Optical Networks, ICTON 2019
978-1-7281-2779-8
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3505681
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact