Purpose: To characterize the short-term results of a newly available self-expanding covered stent (Covera; CR Bard Peripheral Vascular Inc., Murray Hill, New Jersey) for the reconstruction of target vessels in complex aneurysms. Materials and methods: From August 2017 to November 2018, this self-expanding covered stent was used in 17 patients (mean 72.6 ± 7.6 years of age) during endovascular aneurysm repair (EVAR) with hypogastric preservation (11.8%), branched EVAR (29.4%), fenestrated (F)-EVAR (17.6%), chimney + F-EVAR (11.8%), or chimney EVAR (29.4%). In more than 48 stented arteries (2.8 ± 1.1/patient), 25 were preserved using this self-expanding covered stent. Results: All target vessels were successfully preserved. There was no 30-day mortality and 1 in-hospital death. Intraoperative aneurysm exclusion was successful in 14 patients (82.4%) with a perioperative technical success rate of 82.4%. The actuarial survival rate was 93.8% at 6 months and 85.9% at 12 months. Aneurysm sac regression of >5 mm was observed in 4 cases (23.5%), and the sac remained stable in the remaining patients (13 cases [76.5%]). At 12 months, the primary clinical success rate was 76.5%, and assisted primary clinical success rate was 82.4%. No type 3 endoleak was related to a disruption of the reconstruction with the self-expanding covered stent. Conclusions: This new self-expanding covered stent provides good short-term patency in chimneys, branches, or fenestrations. Larger series with long-term follow-up are required to determine if the stent can sustain the mechanical stress to which it will be submitted in these repairs.
Endovascular Treatment of Complex Aneurysms with the Use of Covera Stent Grafts
Colacchio E. C.;
2019
Abstract
Purpose: To characterize the short-term results of a newly available self-expanding covered stent (Covera; CR Bard Peripheral Vascular Inc., Murray Hill, New Jersey) for the reconstruction of target vessels in complex aneurysms. Materials and methods: From August 2017 to November 2018, this self-expanding covered stent was used in 17 patients (mean 72.6 ± 7.6 years of age) during endovascular aneurysm repair (EVAR) with hypogastric preservation (11.8%), branched EVAR (29.4%), fenestrated (F)-EVAR (17.6%), chimney + F-EVAR (11.8%), or chimney EVAR (29.4%). In more than 48 stented arteries (2.8 ± 1.1/patient), 25 were preserved using this self-expanding covered stent. Results: All target vessels were successfully preserved. There was no 30-day mortality and 1 in-hospital death. Intraoperative aneurysm exclusion was successful in 14 patients (82.4%) with a perioperative technical success rate of 82.4%. The actuarial survival rate was 93.8% at 6 months and 85.9% at 12 months. Aneurysm sac regression of >5 mm was observed in 4 cases (23.5%), and the sac remained stable in the remaining patients (13 cases [76.5%]). At 12 months, the primary clinical success rate was 76.5%, and assisted primary clinical success rate was 82.4%. No type 3 endoleak was related to a disruption of the reconstruction with the self-expanding covered stent. Conclusions: This new self-expanding covered stent provides good short-term patency in chimneys, branches, or fenestrations. Larger series with long-term follow-up are required to determine if the stent can sustain the mechanical stress to which it will be submitted in these repairs.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.