Metis is a multi-wavelength coronagraph onboard the European Space Agency (ESA) Solar Orbiter mission. The instrument features an innovative instrument design conceived for simultaneously imaging the Sun's corona in the visible and ultraviolet range. The Metis visible channel employs broad-band, polarized imaging of the visible K-corona, while the UV one uses narrow-band imaging at the HI Ly Į, i.e. 121.6 nm. During the commissioning different acquisitions and activities, performed with both the Metis channels, have been carried out with the aim to check the functioning and the performance of the instrument. In particular, specific observations of stars have been devised to assess the optical alignment of the telescope and to derive the instrument optical parameters such as focal length, PSF and possibly check the optical distortion and the vignetting function. In this paper, the preliminary results obtained for the PSF of both channels and the determination of the scale for the visible channel will be described and discussed. The in-flight obtained data will be compared to those obtained on-ground during the calibration campaign.
In-flight optical performance assessment for the Metis solar coronagraph
Chioetto P.;Casini C.;Slemer A.;Naletto G.;Pelizzo M. G.;
2021
Abstract
Metis is a multi-wavelength coronagraph onboard the European Space Agency (ESA) Solar Orbiter mission. The instrument features an innovative instrument design conceived for simultaneously imaging the Sun's corona in the visible and ultraviolet range. The Metis visible channel employs broad-band, polarized imaging of the visible K-corona, while the UV one uses narrow-band imaging at the HI Ly Į, i.e. 121.6 nm. During the commissioning different acquisitions and activities, performed with both the Metis channels, have been carried out with the aim to check the functioning and the performance of the instrument. In particular, specific observations of stars have been devised to assess the optical alignment of the telescope and to derive the instrument optical parameters such as focal length, PSF and possibly check the optical distortion and the vignetting function. In this paper, the preliminary results obtained for the PSF of both channels and the determination of the scale for the visible channel will be described and discussed. The in-flight obtained data will be compared to those obtained on-ground during the calibration campaign.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.