In the past decade, a new class of hemodialysis (HD) membranes (high retention onset class) became available for clinical use. The high cutoff (HCO) and the medium cutoff (MCO) membranes have wider pores and more uniformity in pore size, allowing an increased clearance of uremic toxins. Owing to the mechanism of backfiltration/internal filtration, middle molecules are dragged by the convective forces, and no substitution solution is needed. The HCO dialyzer is applied in septic patients with acute kidney injury requiring continuous kidney replacement therapy. The immune response is modulated thanks to the removal of inflammatory mediators. Another current application for the HCO dialyzer is in hematology, for patients on HD secondary to myeloma-kidney, since free light chains are more efficiently removed with the HCO membrane, reducing their deleterious effect on the renal tubules. In its turn, the MCO dialyzer is used for maintenance HD patients. A myriad of clinical trials published ...

Disruptive technologies for hemodialysis: medium and high cutoff membranes. Is the future now?

Claudio Ronco
2021

Abstract

In the past decade, a new class of hemodialysis (HD) membranes (high retention onset class) became available for clinical use. The high cutoff (HCO) and the medium cutoff (MCO) membranes have wider pores and more uniformity in pore size, allowing an increased clearance of uremic toxins. Owing to the mechanism of backfiltration/internal filtration, middle molecules are dragged by the convective forces, and no substitution solution is needed. The HCO dialyzer is applied in septic patients with acute kidney injury requiring continuous kidney replacement therapy. The immune response is modulated thanks to the removal of inflammatory mediators. Another current application for the HCO dialyzer is in hematology, for patients on HD secondary to myeloma-kidney, since free light chains are more efficiently removed with the HCO membrane, reducing their deleterious effect on the renal tubules. In its turn, the MCO dialyzer is used for maintenance HD patients. A myriad of clinical trials published ...
File in questo prodotto:
File Dimensione Formato  
unpaywall-bitstream--1493513306.pdf

accesso aperto

Tipologia: Published (Publisher's Version of Record)
Licenza: Creative commons
Dimensione 1.02 MB
Formato Adobe PDF
1.02 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3388938
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 10
  • OpenAlex ND
social impact