Carbon dioxide (CO2) emissions from running waters represent a key component of the global carbon cycle. However, quantifying CO2 fluxes across air-water boundaries remains challenging due to practical difficulties in the estimation of reach-scale standardized gas exchange velocities (k600) and water equilibrium concentrations. Whereas craft-made floating chambers supplied by internal CO2 sensors represent a promising technique to estimate CO2 fluxes from rivers, the existing literature lacks rigorous comparisons among differently designed chambers and deployment techniques. Moreover, as of now the uncertainty of k600 estimates from chamber data has not been evaluated. Here, these issues were addressed by analysing the results of a flume experiment carried out in the Summer of 2019 in the Lun-zer:::Rinnen-Experimental Facility (Austria). During the experiment, 100 runs were performed using two different chamber designs (namely, a standard chamber and a flexible foil chamber with an external floating system and a flexible sealing) and two different deployment modes (drifting and anchored). The runs were performed using various combinations of discharge and channel slope, leading to variable turbulent kinetic energy dissipation rates (1.5 × 10−3 < ε < 1 × 10−1 m2 s−3). Estimates of gas exchange velocities were in line with the existing literature (4 < k600 < 32 m2 s−3), with a general increase in k600 for larger turbulent kinetic energy dissipation rates. The flexible foil chamber gave consistent k600 patterns in response to changes in the slope and/or the flow rate. Moreover, acoustic Doppler velocimeter measurements indicated a limited increase in the turbulence induced by the flexible foil chamber on the flow field (22 % increase in ε, leading to a theoretical 5 % increase in k600). The uncertainty in the estimate of gas exchange velocities was then estimated using a generalized likelihood uncertainty estimation (GLUE) procedure. Overall, uncertainty in k600 was moderate to high, with enhanced uncertainty in high-energy setups. For the anchored mode, the standard deviations of k600 were between 1.6 and 8.2 m d−1 , whereas significantly higher values were obtained in drifting mode. Interestingly, for the standard chamber the uncertainty was larger (+ 20 %) as compared to the flexible foil chamber. Our study suggests that a flexible foil design and the anchored deployment might be useful techniques to enhance the robustness and the accuracy of CO2 measurements in low-order streams. Furthermore , the study demonstrates the value of analytical and numerical tools in the identification of accurate estimations for gas exchange velocities. These findings have important implications for improving estimates of greenhouse gas emissions and reaeration rates in running waters.
Evaluating stream CO2 outgassing via Drifting and Anchored flux chambers in a controlled flume experiment
Vingiani, Filippo
;Durighetto, Nicola
;Botter, Gianluca
2021
Abstract
Carbon dioxide (CO2) emissions from running waters represent a key component of the global carbon cycle. However, quantifying CO2 fluxes across air-water boundaries remains challenging due to practical difficulties in the estimation of reach-scale standardized gas exchange velocities (k600) and water equilibrium concentrations. Whereas craft-made floating chambers supplied by internal CO2 sensors represent a promising technique to estimate CO2 fluxes from rivers, the existing literature lacks rigorous comparisons among differently designed chambers and deployment techniques. Moreover, as of now the uncertainty of k600 estimates from chamber data has not been evaluated. Here, these issues were addressed by analysing the results of a flume experiment carried out in the Summer of 2019 in the Lun-zer:::Rinnen-Experimental Facility (Austria). During the experiment, 100 runs were performed using two different chamber designs (namely, a standard chamber and a flexible foil chamber with an external floating system and a flexible sealing) and two different deployment modes (drifting and anchored). The runs were performed using various combinations of discharge and channel slope, leading to variable turbulent kinetic energy dissipation rates (1.5 × 10−3 < ε < 1 × 10−1 m2 s−3). Estimates of gas exchange velocities were in line with the existing literature (4 < k600 < 32 m2 s−3), with a general increase in k600 for larger turbulent kinetic energy dissipation rates. The flexible foil chamber gave consistent k600 patterns in response to changes in the slope and/or the flow rate. Moreover, acoustic Doppler velocimeter measurements indicated a limited increase in the turbulence induced by the flexible foil chamber on the flow field (22 % increase in ε, leading to a theoretical 5 % increase in k600). The uncertainty in the estimate of gas exchange velocities was then estimated using a generalized likelihood uncertainty estimation (GLUE) procedure. Overall, uncertainty in k600 was moderate to high, with enhanced uncertainty in high-energy setups. For the anchored mode, the standard deviations of k600 were between 1.6 and 8.2 m d−1 , whereas significantly higher values were obtained in drifting mode. Interestingly, for the standard chamber the uncertainty was larger (+ 20 %) as compared to the flexible foil chamber. Our study suggests that a flexible foil design and the anchored deployment might be useful techniques to enhance the robustness and the accuracy of CO2 measurements in low-order streams. Furthermore , the study demonstrates the value of analytical and numerical tools in the identification of accurate estimations for gas exchange velocities. These findings have important implications for improving estimates of greenhouse gas emissions and reaeration rates in running waters.File | Dimensione | Formato | |
---|---|---|---|
bg-18-1223-2021.pdf
accesso aperto
Descrizione: Article
Tipologia:
Versione editoriale
Licenza:
Creative commons
Dimensione
2.71 MB
Formato
Adobe PDF
|
2.71 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.