Introduction: Ground-glass nodules may be the expression of benign conditions, pre-invasive lesions or malignancies. The aim of our study was to evaluate the capability of chest digital tomosynthesis (DTS) in detecting pulmonary ground-glass opacities (GGOs). Methods: An anthropomorphic chest phantom and synthetic nodules were used to simulate pulmonary ground-glass nodules. The nodules were positioned in 3 different regions (apex, hilum and basal); then the phantom was scanned by multi-detector CT (MDCT) and DTS. For each set (nodule-free phantom, nodule in apical zone, nodule in hilar zone, nodule in basal zone) seven different scans (n = 28) were performed varying the following technical parameters: Cu-filter (0.1–0.3 mm), dose rateo (10–25) and X-ray tube voltage (105–125 kVp). Two radiologists in consensus evaluated the DTS images and provided in agreement a visual score: 1 for unidentifiable nodules, 2 for poorly identifiable nodules, 3 for nodules identifiable with fair certainty, 4 for nodules identifiable with absolute certainty. Results: Increasing the dose rateo from 10 to 15, GGOs located in the apex and in the basal zone were better identified (from a score = 2 to a score = 3). GGOs located in the hilar zone were not visible even with a higher dose rate. Intermediate density GGOs had a good visibility score (score = 3) and it did not improve by varying technical parameters. A progressive increase of voltage (from 105 kVp to 125 kVp) did not provide a better nodule visibility. Conclusion: DTS with optimized technical parameters can identify GGOs, in particular those with a diameter greater than 10 mm. Implications for practice: DTS could have a role in the follow-up of patients with known GGOs identified in lung apex or base region.

Digital tomosynthesis and ground glass nodules: Optimization of acquisition protocol. A phantom study

Quaia E;
2021

Abstract

Introduction: Ground-glass nodules may be the expression of benign conditions, pre-invasive lesions or malignancies. The aim of our study was to evaluate the capability of chest digital tomosynthesis (DTS) in detecting pulmonary ground-glass opacities (GGOs). Methods: An anthropomorphic chest phantom and synthetic nodules were used to simulate pulmonary ground-glass nodules. The nodules were positioned in 3 different regions (apex, hilum and basal); then the phantom was scanned by multi-detector CT (MDCT) and DTS. For each set (nodule-free phantom, nodule in apical zone, nodule in hilar zone, nodule in basal zone) seven different scans (n = 28) were performed varying the following technical parameters: Cu-filter (0.1–0.3 mm), dose rateo (10–25) and X-ray tube voltage (105–125 kVp). Two radiologists in consensus evaluated the DTS images and provided in agreement a visual score: 1 for unidentifiable nodules, 2 for poorly identifiable nodules, 3 for nodules identifiable with fair certainty, 4 for nodules identifiable with absolute certainty. Results: Increasing the dose rateo from 10 to 15, GGOs located in the apex and in the basal zone were better identified (from a score = 2 to a score = 3). GGOs located in the hilar zone were not visible even with a higher dose rate. Intermediate density GGOs had a good visibility score (score = 3) and it did not improve by varying technical parameters. A progressive increase of voltage (from 105 kVp to 125 kVp) did not provide a better nodule visibility. Conclusion: DTS with optimized technical parameters can identify GGOs, in particular those with a diameter greater than 10 mm. Implications for practice: DTS could have a role in the follow-up of patients with known GGOs identified in lung apex or base region.
2021
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3376036
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
  • OpenAlex ND
social impact