Design and construction of CLT structures is now known throughout the world thanks to its known properties, its high thermal resistance to low energy consumption and its low environmental impact. For these reasons, the studies and research on the acoustic performance analysis of these wood panels have also been very successful in recent years. This document aims to present the continuation of the investigative work carried out by Isolgomma on CLT structures, completing the study on the acoustic behaviour of floors with wall and flanking transmission analysis. Therefore, the results of the laboratory acoustic characterization of the CLT walls are presented with the application of different techniques for improving the possible performances, according to the standards of the ISO 10140 series. Furthermore, the considerations related to the study carried out on the joints of the structures are reported. CLT on a large-scale test configuration, according to the standards of the ISO 10848 series. Through this analysis it was possible to obtain the vibration reduction indices both of the bare CLT structure and of the isolated structure through the insertion of a specific anti-vibration rubber mat.
Acoustics behaviour of CLT structure: Transmission loss, impact noise insulation and flanking transmission evaluations
Granzotto N.;Di Bella A.
2020
Abstract
Design and construction of CLT structures is now known throughout the world thanks to its known properties, its high thermal resistance to low energy consumption and its low environmental impact. For these reasons, the studies and research on the acoustic performance analysis of these wood panels have also been very successful in recent years. This document aims to present the continuation of the investigative work carried out by Isolgomma on CLT structures, completing the study on the acoustic behaviour of floors with wall and flanking transmission analysis. Therefore, the results of the laboratory acoustic characterization of the CLT walls are presented with the application of different techniques for improving the possible performances, according to the standards of the ISO 10140 series. Furthermore, the considerations related to the study carried out on the joints of the structures are reported. CLT on a large-scale test configuration, according to the standards of the ISO 10848 series. Through this analysis it was possible to obtain the vibration reduction indices both of the bare CLT structure and of the isolated structure through the insertion of a specific anti-vibration rubber mat.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.