The use of cross-concentric braced steel frames is still an effective way to realize earthquake-resistant buildings, thanks to the simplicity in the design and realization, assuring good strength, stiffness and ductility, provided that capacity design be fulfilled. Results from non-linear static and dynamic analyses of steel frames braced with cross-concentric rectangular plates are presented to discuss some significant design aspects that play a key role in the definition of the hysteretic dissipative response of such structures. Parametric cyclic analyses were performed to assess the peak- and post-buckling lateral strength and the dissipative capacity of a small- and a full-scale frame, varying the non-dimensional slendemess of the bracing plates. Then, results of incremental dynamic analyses of a one-, three-, six- and ten-storey building are discussed to evaluate the behaviour factor for this structural typology, as function of inter-storey drift. Results from the parametric and incremental analyses give the optimal range of non-dimensional slenderness of the bracing plates as a compromise between limited overstrength and good dissipative capacity and confirm the behaviour factor currently provided by Eurocode, relating it with an expected inter-storey lateral drift. (C) 2019 Elsevier Ltd. All rights reserved.

Seismic capacity of steel frames braced with cross-concentric rectangular plates: Non-linear analyses

Trutalli, D;De Stefani, L;Marchi, L;Scotta, R
2019

Abstract

The use of cross-concentric braced steel frames is still an effective way to realize earthquake-resistant buildings, thanks to the simplicity in the design and realization, assuring good strength, stiffness and ductility, provided that capacity design be fulfilled. Results from non-linear static and dynamic analyses of steel frames braced with cross-concentric rectangular plates are presented to discuss some significant design aspects that play a key role in the definition of the hysteretic dissipative response of such structures. Parametric cyclic analyses were performed to assess the peak- and post-buckling lateral strength and the dissipative capacity of a small- and a full-scale frame, varying the non-dimensional slendemess of the bracing plates. Then, results of incremental dynamic analyses of a one-, three-, six- and ten-storey building are discussed to evaluate the behaviour factor for this structural typology, as function of inter-storey drift. Results from the parametric and incremental analyses give the optimal range of non-dimensional slenderness of the bracing plates as a compromise between limited overstrength and good dissipative capacity and confirm the behaviour factor currently provided by Eurocode, relating it with an expected inter-storey lateral drift. (C) 2019 Elsevier Ltd. All rights reserved.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3343343
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
  • OpenAlex ND
social impact