Several patients undergoing chronic renal replacement therapy present problems related to their vascular access. Low blood flows and high rates of recirculation are common in such patients in which, for this reason, it becomes difficult to apply highly efficient techniques or techniques where diffusion and convection are combined as in hemodiafiltration. In these patients we studied the possibility of partially recirculating the blood in the extracorporeal circuit in order to increase the flow rate per single hollow fiber; we defined our system ''double pass dialysis''. We evaluated the system's efficiency in 12 patients during 24 dialysis sessions: 12 high flux dialysis sessions (without reinfusion) and 12 hemodiafiltration sessions (9 liters reinfusion). Different surfaces of polyacrylonitrile dialyzers were utilized (1.3-1.7-2.1 sqm) at 250 and 350 ml/min of blood flow with or without 100 ml/min of recirculation. During each dialysis session blood and dialysate samples were taken in order to calculate BUN, Creatinine, Phosphate and Inuline clearances from both the blood and dialysate side. The clearances of low molecular weight solutes were not really influenced by the artificial increase of the blood flow, but on the other hand, the clearances of higher molecular weight solutes increased from 10 to 30% during both high flux dialysis and hemodiafiltration with recirculation. This increase was evident mostly in hemodiafiltration suggesting that the cleaning effect on the membrane has a positive impact on the permeability. The good clinical results obtained with the double pass dialysis show that the system is safe and reliable and may become a valid support in critical situations in order to reach adequate dialysis treatment.

DOUBLE-PASS DIALYSIS - A NEW METHOD OF RENAL REPLACEMENT IN PATIENTS WITH MALFUNCTIONING VASCULAR ACCESS

RONCO C;
1994

Abstract

Several patients undergoing chronic renal replacement therapy present problems related to their vascular access. Low blood flows and high rates of recirculation are common in such patients in which, for this reason, it becomes difficult to apply highly efficient techniques or techniques where diffusion and convection are combined as in hemodiafiltration. In these patients we studied the possibility of partially recirculating the blood in the extracorporeal circuit in order to increase the flow rate per single hollow fiber; we defined our system ''double pass dialysis''. We evaluated the system's efficiency in 12 patients during 24 dialysis sessions: 12 high flux dialysis sessions (without reinfusion) and 12 hemodiafiltration sessions (9 liters reinfusion). Different surfaces of polyacrylonitrile dialyzers were utilized (1.3-1.7-2.1 sqm) at 250 and 350 ml/min of blood flow with or without 100 ml/min of recirculation. During each dialysis session blood and dialysate samples were taken in order to calculate BUN, Creatinine, Phosphate and Inuline clearances from both the blood and dialysate side. The clearances of low molecular weight solutes were not really influenced by the artificial increase of the blood flow, but on the other hand, the clearances of higher molecular weight solutes increased from 10 to 30% during both high flux dialysis and hemodiafiltration with recirculation. This increase was evident mostly in hemodiafiltration suggesting that the cleaning effect on the membrane has a positive impact on the permeability. The good clinical results obtained with the double pass dialysis show that the system is safe and reliable and may become a valid support in critical situations in order to reach adequate dialysis treatment.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3293420
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 6
  • OpenAlex ND
social impact