Perfusion computed tomography (PCT) is a means to rapidly and easily evaluate cerebral perfusion in patients presenting with acute stroke symptoms, which provides insights into capillary-level hemodynamics. In this study, we used PCT to analyze the 3-dimensional dialysate flow in a low-flux hemodialyzer equipped with a standard fiber bundle. The dynamic CT studies were performed with 64-channel multi-detector row CT (MDCT) at a dialysate flow rate of 500 ml/min and a 1.0 ml/sec injection rate of contrast agent. Central volume principle was used to calculate hydrodynamic parameters by deconvolution of time-density curves (TDCs). Functional maps of dialysate flow (DF), dialysate volume (DV), and mean transit time (MTT) could quantitatively describe the dialysate flow maldistribution, variations in fiber packing, and perfusion pressure distribution in a hemodialyzer, respectively. PCT by means of analysis was able to overcome the limitations of conventional imaging techniques for analyzing dialysate flow distributions in hollow-fiber dialyzers. Not only local hydrodynamic phenomena at microscopic level but also macroscopic flow behavior of dialysate were visualized quantitatively. Therefore, we concluded that PCT is a quantitative analysis method to provide better insights into hydrodynamics of hollow-fiber dialyzers and is expected to contribute to optimization of artificial kidneys.

Three-dimensional dialysate flow analysis in a hollow-fiber dialyzer by perfusion computed tomography

Ronco C
2008

Abstract

Perfusion computed tomography (PCT) is a means to rapidly and easily evaluate cerebral perfusion in patients presenting with acute stroke symptoms, which provides insights into capillary-level hemodynamics. In this study, we used PCT to analyze the 3-dimensional dialysate flow in a low-flux hemodialyzer equipped with a standard fiber bundle. The dynamic CT studies were performed with 64-channel multi-detector row CT (MDCT) at a dialysate flow rate of 500 ml/min and a 1.0 ml/sec injection rate of contrast agent. Central volume principle was used to calculate hydrodynamic parameters by deconvolution of time-density curves (TDCs). Functional maps of dialysate flow (DF), dialysate volume (DV), and mean transit time (MTT) could quantitatively describe the dialysate flow maldistribution, variations in fiber packing, and perfusion pressure distribution in a hemodialyzer, respectively. PCT by means of analysis was able to overcome the limitations of conventional imaging techniques for analyzing dialysate flow distributions in hollow-fiber dialyzers. Not only local hydrodynamic phenomena at microscopic level but also macroscopic flow behavior of dialysate were visualized quantitatively. Therefore, we concluded that PCT is a quantitative analysis method to provide better insights into hydrodynamics of hollow-fiber dialyzers and is expected to contribute to optimization of artificial kidneys.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3293415
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 3
  • OpenAlex ND
social impact