A major modification of the RFX-mod toroidal load assembly has been decided in order to improve passive MHD control and to minimize the braking torque on the plasma, thus extending the operational space in both RFP and Tokamak configurations. With the removal of the vacuum vessel, the support structure will be modified in order to obtain a new vacuum-tight chamber and the first wall tiles will be directly in front of the passive stabilizing shell inside of it, so increasing both the poloidal cross section and the plasma-shell proximity. This implies the design of a new vacuum fit electromagnetic measurement system. The new local probes will be installed in vacuum onto the copper shell, behind the graphite tiles, and shall operate up to a maximum temperature of 180°C to allow for baking cycles for first wall conditioning. Because of the reduced room available, tri-axial pickup probes have been designed, with the additional advantage of allowing the minimization of alignment errors. The paper describes the detailed design of the new probe set, in particular highlighting advantages and effectiveness of different probe solutions. Preliminary tests carried out on local probe prototypes to characterize their electromagnetic behaviour are also reported.

Design of the new electromagnetic measurement system for RFX-mod upgrade

N. Marconato
Writing – Original Draft Preparation
;
P. Bettini;L. Marrelli;
2019

Abstract

A major modification of the RFX-mod toroidal load assembly has been decided in order to improve passive MHD control and to minimize the braking torque on the plasma, thus extending the operational space in both RFP and Tokamak configurations. With the removal of the vacuum vessel, the support structure will be modified in order to obtain a new vacuum-tight chamber and the first wall tiles will be directly in front of the passive stabilizing shell inside of it, so increasing both the poloidal cross section and the plasma-shell proximity. This implies the design of a new vacuum fit electromagnetic measurement system. The new local probes will be installed in vacuum onto the copper shell, behind the graphite tiles, and shall operate up to a maximum temperature of 180°C to allow for baking cycles for first wall conditioning. Because of the reduced room available, tri-axial pickup probes have been designed, with the additional advantage of allowing the minimization of alignment errors. The paper describes the detailed design of the new probe set, in particular highlighting advantages and effectiveness of different probe solutions. Preliminary tests carried out on local probe prototypes to characterize their electromagnetic behaviour are also reported.
File in questo prodotto:
File Dimensione Formato  
Design of the new electromagnetic measurement system for RFX-mod.pdf

Open Access dal 23/01/2021

Descrizione: Articolo principale
Tipologia: Postprint (accepted version)
Licenza: Accesso libero
Dimensione 2.87 MB
Formato Adobe PDF
2.87 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3288717
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 11
social impact