The use of liquefied natural gas (LNG) as a marine fuel is rapidly growing because of the possible economic advantages over conventional fuels and stricter environmental regulations. Production of LNG is energy intensive because of the required temperature level of around -160°C. Three main types of refrigeration cycles have been developed. The present work focuses on the comparison of six expander-based configurations, which in spite of the higher power consumption, are more compact, flexible and easier to operate. They are optimised from a thermodynamic perspective: the exergetic efficiency is found to range between 17 % and 33 % for a specific power consumption down to 1340 kJ/kg. Multi-objective optimisations are performed to simultaneously minimise the net power consumption and the heat transfer conductance as an indicator of the required heat transfer area. The latter ranges between 50 kW/K and 300 kW/K. A trade-off between power consumption and heat transfer area is found, which justifies a further economic analysis. A simplified economic analysis is set based on a discounted cash flow model. The unitary profit ranges between 0.5 and 0.9 DKK/kg of produced LNG. The most profitable expander-based configuration is the dual-refrigerant cycle with nitrogen in the bottoming refrigeration cycle. Finally, the influence of the cost correlations on the economic outcome is assessed: the compressors represent the major costs, which leads to the coincidence of the thermodynamic and economic optima.

Techno-economic analysis of expander-based configurations for natural gas liquefaction

NAGY, MATTEO
;
Lazzaretto A.
2017

Abstract

The use of liquefied natural gas (LNG) as a marine fuel is rapidly growing because of the possible economic advantages over conventional fuels and stricter environmental regulations. Production of LNG is energy intensive because of the required temperature level of around -160°C. Three main types of refrigeration cycles have been developed. The present work focuses on the comparison of six expander-based configurations, which in spite of the higher power consumption, are more compact, flexible and easier to operate. They are optimised from a thermodynamic perspective: the exergetic efficiency is found to range between 17 % and 33 % for a specific power consumption down to 1340 kJ/kg. Multi-objective optimisations are performed to simultaneously minimise the net power consumption and the heat transfer conductance as an indicator of the required heat transfer area. The latter ranges between 50 kW/K and 300 kW/K. A trade-off between power consumption and heat transfer area is found, which justifies a further economic analysis. A simplified economic analysis is set based on a discounted cash flow model. The unitary profit ranges between 0.5 and 0.9 DKK/kg of produced LNG. The most profitable expander-based configuration is the dual-refrigerant cycle with nitrogen in the bottoming refrigeration cycle. Finally, the influence of the cost correlations on the economic outcome is assessed: the compressors represent the major costs, which leads to the coincidence of the thermodynamic and economic optima.
2017
Proc. of: ECOS2017, 30th Int. Conference on Efficiency, Cost, Optimisation, Simulation and Environmental Impact of Energy Systems
ECOS2017, 30th Int. Conference on Efficiency, Cost, Optimisation, Simulation and Environmental Impact of Energy Systems
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3254601
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact