On a droplet-based Labs-on-Chip (LoC) device, tiny volumes of fluids, so-called droplets, flow in channels of micrometer scale. The droplets contain chemical/biological samples that are processed by different modules on the LoC. In current solutions, an LoC is a single-purpose device that is designed for a specific application, which limits its flexibility. In order to realize a multi-purpose system, different modules are interconnected in a microfluidic network - yielding so-called Networked LoCs (NLoCs). In NLoCs, the droplets are routed to the desired modules by exploiting hydrodynamic forces. A well established topology for NLoCs are ring networks. However, the addressing schemes provided so far in the literature only allow to address multiple modules by re-injecting the droplet at the source every time, which is a very complex task and increases the risk of ruining the sample. In this work, we address this issue by revising the design of the network nodes, which include the modules. A novel configuration allows the droplet to undergo processing several times in cascade by different modules with a single injection. Simulating the trajectory of the droplets across the network confirmed the validity of our approach.

Addressing multiple nodes in networked labs-on-chips without payload re-injection

Biral, Andrea
;
Zanella, Andrea
;
2017

Abstract

On a droplet-based Labs-on-Chip (LoC) device, tiny volumes of fluids, so-called droplets, flow in channels of micrometer scale. The droplets contain chemical/biological samples that are processed by different modules on the LoC. In current solutions, an LoC is a single-purpose device that is designed for a specific application, which limits its flexibility. In order to realize a multi-purpose system, different modules are interconnected in a microfluidic network - yielding so-called Networked LoCs (NLoCs). In NLoCs, the droplets are routed to the desired modules by exploiting hydrodynamic forces. A well established topology for NLoCs are ring networks. However, the addressing schemes provided so far in the literature only allow to address multiple modules by re-injecting the droplet at the source every time, which is a very complex task and increases the risk of ruining the sample. In this work, we address this issue by revising the design of the network nodes, which include the modules. A novel configuration allows the droplet to undergo processing several times in cascade by different modules with a single injection. Simulating the trajectory of the droplets across the network confirmed the validity of our approach.
2017
IEEE International Conference on Communications
2017 IEEE International Conference on Communications, ICC 2017
9781467389990
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3249022
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 4
  • OpenAlex ND
social impact