We report a successful combined approach of transvenous mechanical pacing lead extraction and stent angioplasty for superior baffle occlusion in a young woman with D-transposition of great artery after Mustard procedure. After having extracted the pacing leads, the baffle was easily stented, thanks to the channel left by the extracted leads. Eventually, a new pacing lead was implanted into the pulmonic ventricle through the stented baffle. Our report demonstrates the safeness and feasibility of a combined interventional approach in avoiding the need for surgery.
Successful transvenous mechanical lead extraction and stent implantation in a patient after Mustard palliation for D-transposition of great arteries and superior vena cava syndrome
MIGLIORE, FEDERICO;FERRETTO, SONIA;CASTALDI, BIAGIO;MASCHIETTO, NICOLA;LEONI, LOIRA
2016
Abstract
We report a successful combined approach of transvenous mechanical pacing lead extraction and stent angioplasty for superior baffle occlusion in a young woman with D-transposition of great artery after Mustard procedure. After having extracted the pacing leads, the baffle was easily stented, thanks to the channel left by the extracted leads. Eventually, a new pacing lead was implanted into the pulmonic ventricle through the stented baffle. Our report demonstrates the safeness and feasibility of a combined interventional approach in avoiding the need for surgery.File in questo prodotto: