OBJECTIVE To evaluate the correlation coefficient of the ratio between diameter of the caudal vena cava (CVC) and diameter of the aorta (Ao) in dogs as determined ultrasonographically with systolic pressure variation (SPV). ANIMALS 14 client-owned dogs (9 females and 5 males; mean ± SD age, 73 ± 40 months; mean body weight, 22 ± 7 kg) that underwent anesthesia for repair of skin wounds. PROCEDURES Anesthesia was induced. Controlled mechanical ventilation with a peak inspiratory pressure of 8 cm H2O was immediately started, and SPV was measured. During a brief period of suspension of ventilation, CVC-to-Ao ratio was measured on a transverse right-lateral intercostal ultrasonographic image obtained at the level of the porta hepatis. When the SPV was ≥ 4 mm Hg, at least 1 bolus (3 to 4 mL/kg) of Hartmann solution was administered IV during a 1-minute period. Bolus administration was stopped and the CVC-to-Ao ratio measured when SPV was < 4 mm Hg. Correlation coefficient analysis was perfo...

Correlation of the ratio of caudal vena cava diameter and aorta diameter with systolic pressure variation in anesthetized dogs

MENEGHINI, CATERINA;FRANCI, PAOLO
2016

Abstract

OBJECTIVE To evaluate the correlation coefficient of the ratio between diameter of the caudal vena cava (CVC) and diameter of the aorta (Ao) in dogs as determined ultrasonographically with systolic pressure variation (SPV). ANIMALS 14 client-owned dogs (9 females and 5 males; mean ± SD age, 73 ± 40 months; mean body weight, 22 ± 7 kg) that underwent anesthesia for repair of skin wounds. PROCEDURES Anesthesia was induced. Controlled mechanical ventilation with a peak inspiratory pressure of 8 cm H2O was immediately started, and SPV was measured. During a brief period of suspension of ventilation, CVC-to-Ao ratio was measured on a transverse right-lateral intercostal ultrasonographic image obtained at the level of the porta hepatis. When the SPV was ≥ 4 mm Hg, at least 1 bolus (3 to 4 mL/kg) of Hartmann solution was administered IV during a 1-minute period. Bolus administration was stopped and the CVC-to-Ao ratio measured when SPV was < 4 mm Hg. Correlation coefficient analysis was perfo...
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3198030
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 28
  • OpenAlex ND
social impact