OBJECTIVES The aim of this study was to evaluate the pathophysiological features and response to primary percutaneous coronary intervention (PCI) of nonruptured/eroded plaque versus ruptured plaque as a cause of ST-segment elevation myocardial infarction (STEMI). BACKGROUND Autopsy series identified nonruptured/eroded plaque and ruptured plaque as the principal pathological substrates underlying coronary thrombosis in STEM I. The real incidence of different plaque morphologies, associated biological factors, superimposed thrombus, and their interaction with primary PCI remain Largely unknown. METHODS In a prospective study, 140 patients with STEMI underwent optical coherence tomography of the infarct-related artery (IRA) before PCI, after everolimus-eluting stent implantation and at 9-month follow-up. Histopathology and immunohistochemistry of thrombus aspirates and serum biomarkers were assessed at baseline. RESULTS Culprit plaque morphology was adjudicated in 97 patients: 32 plaques (33.0%) with an intact fibrous cap (IFC), 63 (64.9%) plaques with a ruptured fibrous cap (RFC), and 2 (2.1%) spontaneous dissections. Patients with an IFC and RFC had similar clinical characteristics, and serum inflammatory and platelets biomarkers. An IFC presented more frequently with a patent IRA (56.2% vs. 34.9%; p = 0.047), and had fewer Lipid areas (Lipid-rich areas: 75.0% vs. 100.0%; p < 0.001) and Less residual thrombus before stenting (white thrombus: 0.41 mm(3) vs. 1.52 mm(3); p = 0.001; red thrombus: 0 mm(3) vs. 0.29 mm(3); p = 0.001) with a lower peak of creatine kinase-myocardial band (66.6 IU/L vs. 149.8 IU/l.; p = 0.025). At the 9-month optical coherence tomography, IFC and RFC had similar high rates of stent strut coverage (92.5% vs. 91.2%; p = 0.15) and similar percentage of volume obstruction (12.6% vs. 10.2%; p = 0.27). No significant differences in clinical outcomes were observed up to 2 years. CONCLUSIONS In the present study, an IFC was observed at the culprit Lesion site of one-third of STEMIs. IFC, compared with RFC, was associated with higher rates of patent IRA at first angiography, fewer lipid areas, and residual endoluminal thrombus. However, no difference in vascular response to everolimus-eluting stent was observed. (Optical Coherence Tomography Assessment of Gender Diversity in Primary Angioplasty [OCTAVIA]; NCT01377207).

Eroded versus ruptured plaques at the culprit site of STEMI: In vivo pathophysiological features and response to primary PCI

TARANTINI, GIUSEPPE;
2015

Abstract

OBJECTIVES The aim of this study was to evaluate the pathophysiological features and response to primary percutaneous coronary intervention (PCI) of nonruptured/eroded plaque versus ruptured plaque as a cause of ST-segment elevation myocardial infarction (STEMI). BACKGROUND Autopsy series identified nonruptured/eroded plaque and ruptured plaque as the principal pathological substrates underlying coronary thrombosis in STEM I. The real incidence of different plaque morphologies, associated biological factors, superimposed thrombus, and their interaction with primary PCI remain Largely unknown. METHODS In a prospective study, 140 patients with STEMI underwent optical coherence tomography of the infarct-related artery (IRA) before PCI, after everolimus-eluting stent implantation and at 9-month follow-up. Histopathology and immunohistochemistry of thrombus aspirates and serum biomarkers were assessed at baseline. RESULTS Culprit plaque morphology was adjudicated in 97 patients: 32 plaques (33.0%) with an intact fibrous cap (IFC), 63 (64.9%) plaques with a ruptured fibrous cap (RFC), and 2 (2.1%) spontaneous dissections. Patients with an IFC and RFC had similar clinical characteristics, and serum inflammatory and platelets biomarkers. An IFC presented more frequently with a patent IRA (56.2% vs. 34.9%; p = 0.047), and had fewer Lipid areas (Lipid-rich areas: 75.0% vs. 100.0%; p < 0.001) and Less residual thrombus before stenting (white thrombus: 0.41 mm(3) vs. 1.52 mm(3); p = 0.001; red thrombus: 0 mm(3) vs. 0.29 mm(3); p = 0.001) with a lower peak of creatine kinase-myocardial band (66.6 IU/L vs. 149.8 IU/l.; p = 0.025). At the 9-month optical coherence tomography, IFC and RFC had similar high rates of stent strut coverage (92.5% vs. 91.2%; p = 0.15) and similar percentage of volume obstruction (12.6% vs. 10.2%; p = 0.27). No significant differences in clinical outcomes were observed up to 2 years. CONCLUSIONS In the present study, an IFC was observed at the culprit Lesion site of one-third of STEMIs. IFC, compared with RFC, was associated with higher rates of patent IRA at first angiography, fewer lipid areas, and residual endoluminal thrombus. However, no difference in vascular response to everolimus-eluting stent was observed. (Optical Coherence Tomography Assessment of Gender Diversity in Primary Angioplasty [OCTAVIA]; NCT01377207).
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3196820
Citazioni
  • ???jsp.display-item.citation.pmc??? 28
  • Scopus 93
  • ???jsp.display-item.citation.isi??? 19
  • OpenAlex ND
social impact