In view of the construction of novel and high-sensitive instrumentation for the emerging ISOL facilities new prototypes have being implemented and tested. The contribution focuses at the investigation of the detection efficiency of an innovative silicon-pad prototype, which is the key element for the construction of the TRACE array, pursued for the SPES facility based at the Legnaro National Laboratories (Italy). The inter-pad size has been estimated by using a commercial 100-MHz-14-bit CAEN digitizer for sampling the signals obtained by an alpha-source scan over the inter-pad region.
Characterization of a highly-segmented silicon prototype for the TRACE array
GELAIN, MICHELE;MENGONI, DANIELE;LUNARDI, SANTO;
2014
Abstract
In view of the construction of novel and high-sensitive instrumentation for the emerging ISOL facilities new prototypes have being implemented and tested. The contribution focuses at the investigation of the detection efficiency of an innovative silicon-pad prototype, which is the key element for the construction of the TRACE array, pursued for the SPES facility based at the Legnaro National Laboratories (Italy). The inter-pad size has been estimated by using a commercial 100-MHz-14-bit CAEN digitizer for sampling the signals obtained by an alpha-source scan over the inter-pad region.File in questo prodotto:
File | Dimensione | Formato | |
---|---|---|---|
unpaywall-bitstream-1720944495
accesso aperto
Tipologia:
Published (publisher's version)
Licenza:
Creative commons
Dimensione
914.13 kB
Formato
Unknown
|
914.13 kB | Unknown | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.