Better energy efficiency of ground coupled heat pump systems in comparison with traditional applications leads to continued growth in the number of installations for space conditioning. The solution with vertical heat exchangers is the most widespread. The design of the borehole heat exchangers (BHEs) is a nodal point, both from an energy efficiency and an economic point of view. In literature, several methods to design these systems are available. However, to promote their application, easy-to-use procedures are required; furthermore designers very often are discouraged from the use of not-open or complicated computational tools. Among the literature models, the ASHRAE method is surely the simplest procedure and, as a consequence, it is suitable for this goal. In this approach, sizing of the BHE length is strongly affected by the parameter named penalty temperature, which is an index to evaluate the long-term behaviour of the borehole field. In this paper, a review of this index is reported and in addition a new approach for its evaluation is presented. Furthermore, a detailed analysis of the proposed method is performed on a real case-study building with only heating conditioning

Design of borehole heat exchangers for ground-source heat pumps: A literature review, methodology comparison and analysis on the penalty temperature

DE CARLI, MICHELE;ZARRELLA, ANGELO
2012

Abstract

Better energy efficiency of ground coupled heat pump systems in comparison with traditional applications leads to continued growth in the number of installations for space conditioning. The solution with vertical heat exchangers is the most widespread. The design of the borehole heat exchangers (BHEs) is a nodal point, both from an energy efficiency and an economic point of view. In literature, several methods to design these systems are available. However, to promote their application, easy-to-use procedures are required; furthermore designers very often are discouraged from the use of not-open or complicated computational tools. Among the literature models, the ASHRAE method is surely the simplest procedure and, as a consequence, it is suitable for this goal. In this approach, sizing of the BHE length is strongly affected by the parameter named penalty temperature, which is an index to evaluate the long-term behaviour of the borehole field. In this paper, a review of this index is reported and in addition a new approach for its evaluation is presented. Furthermore, a detailed analysis of the proposed method is performed on a real case-study building with only heating conditioning
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2578075
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 73
  • ???jsp.display-item.citation.isi??? 67
  • OpenAlex ND
social impact