Distribution of the hot storage in a multitank system may be a suitable way to assure stratification in DHW solar heating plants of medium and great sizes. The possible connections for the various tanks are manifold: three different working ways are considered in this paper. Performances are analyzed during one year through TRNSYS computing program and the results are compared.
Comparison of Multitank Storage DHW Heating Solar Plants.[CONFRONTO FRA IMPIANTI SOLARI CON ACCUMULO A SERBATOIO MULTIPLO.]
LAZZARIN, RENATO;ROSSETTO, LUISA;SCHIBUOLA, LUIGI
1983
Abstract
Distribution of the hot storage in a multitank system may be a suitable way to assure stratification in DHW solar heating plants of medium and great sizes. The possible connections for the various tanks are manifold: three different working ways are considered in this paper. Performances are analyzed during one year through TRNSYS computing program and the results are compared.File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate