The role of light emission components unrelated to the Stern-Volmer kinetic model (SV), in the curvature of the Stern-Volmer model (SV) was evidenced and the discrepancy often encountered between calibrations with light intensity, I, and luminescence lifetime, , was explained by means of mathematical models applied to experimental data.1 Sensing membranes prepared embedding tris-4,7-diphenyl-1,10-phenanthroline (Ru(dpp), platinum(II) meso-tetra-phenyl porphyrin (PtTPP) and palladium(II) meso tetra (pentafluoro-phenyl) porphyrin, (PdFTPP) in a polysulfone matrix, were used to confirm the proposed theory2. Multisite hypotheses or other correction procedures3 must be invoked only after a careful evaluation of the background light really present in the system. A new form of the SV equation having the advantage to obtain the and the effective background with a simple un-weighed regression method was proposed and compare to the “classical” SV requiring the knowledge of the background and a weighed regression. Experimental results confirmed the theory for what concerns the concentration limit for the determination of oxygen which may be theoretically determined. Ru(dpp)OS, PtTPP and PdFTPP membranes may determine oxygen mixtures up to 100, 60.7 and 19.0 %, respectively, with a resolution of 2%. Narrower working intervals are explorable if better resolution is required.

Influence of the real background signal on the linearity of the Stern-Volmer calibration for the determination of molecular oxygen with optical sensors

BADOCCO, DENIS;MONDIN, ANDREA;PASTORE, PAOLO
2009

Abstract

The role of light emission components unrelated to the Stern-Volmer kinetic model (SV), in the curvature of the Stern-Volmer model (SV) was evidenced and the discrepancy often encountered between calibrations with light intensity, I, and luminescence lifetime, , was explained by means of mathematical models applied to experimental data.1 Sensing membranes prepared embedding tris-4,7-diphenyl-1,10-phenanthroline (Ru(dpp), platinum(II) meso-tetra-phenyl porphyrin (PtTPP) and palladium(II) meso tetra (pentafluoro-phenyl) porphyrin, (PdFTPP) in a polysulfone matrix, were used to confirm the proposed theory2. Multisite hypotheses or other correction procedures3 must be invoked only after a careful evaluation of the background light really present in the system. A new form of the SV equation having the advantage to obtain the and the effective background with a simple un-weighed regression method was proposed and compare to the “classical” SV requiring the knowledge of the background and a weighed regression. Experimental results confirmed the theory for what concerns the concentration limit for the determination of oxygen which may be theoretically determined. Ru(dpp)OS, PtTPP and PdFTPP membranes may determine oxygen mixtures up to 100, 60.7 and 19.0 %, respectively, with a resolution of 2%. Narrower working intervals are explorable if better resolution is required.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2484463
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact