Monitoring depth of anesthesia may improve anesthetic dosing and postanesthetic recovery in obese patients. Sixty morbidly obese patients undergoing laparo- scopic adjustable gastric bandage (LAGB) were randomly assigned to receive anesthesia with sevoflurane titrated by either standard clinical parameters (SCP) (target = baseline hemodynamic parameters±20%) or by A-line ARX index (AAI) (target = 20 ± 5). Heart rate, arterial blood pressure, inspiratory and expiratory gas concentrations, and AAI were recorded in all patients at 5-min intervals, but AAI was made available only to the anesthesiologist assigned to AAI-monitored patients. Emergence times in surgery room and recovery times in postanesthesia care unit (PACU) were recorded at 1- and 30-min intervals. Mean intraoperative values of AAI were higher in AAI-monitored than in SCP- monitored patients (22.5 vs 15.0, p = 0.001). Compared to SCP monitoring, AAI monitoring reduced consumption of sevoflurane by 20% (p = 0.014), times to eye opening by 2.4 min (p = 0.001) and to extubation by 2.5 min (p = 0.009) and to achieve SpO2 92% in room air by 17 min (p=0.001). Aldrete scores were higher in AAI- than in SCP-monitored patients at arrival in PACU (p = 0.035), but Aldrete scores ≥9 were attained in similar times. AAI monitoring can improve titration of and recovery from sevoflurane for LAGB.

Effects of A-Line Autoregression Index (AAI) Monitoring on Recovery After Sevoflurane Anesthesia for Bariatric Surgery

FREO, ULDERICO;CARRON, MICHELE;NITTI, DONATO;ORI, CARLO
2011

Abstract

Monitoring depth of anesthesia may improve anesthetic dosing and postanesthetic recovery in obese patients. Sixty morbidly obese patients undergoing laparo- scopic adjustable gastric bandage (LAGB) were randomly assigned to receive anesthesia with sevoflurane titrated by either standard clinical parameters (SCP) (target = baseline hemodynamic parameters±20%) or by A-line ARX index (AAI) (target = 20 ± 5). Heart rate, arterial blood pressure, inspiratory and expiratory gas concentrations, and AAI were recorded in all patients at 5-min intervals, but AAI was made available only to the anesthesiologist assigned to AAI-monitored patients. Emergence times in surgery room and recovery times in postanesthesia care unit (PACU) were recorded at 1- and 30-min intervals. Mean intraoperative values of AAI were higher in AAI-monitored than in SCP- monitored patients (22.5 vs 15.0, p = 0.001). Compared to SCP monitoring, AAI monitoring reduced consumption of sevoflurane by 20% (p = 0.014), times to eye opening by 2.4 min (p = 0.001) and to extubation by 2.5 min (p = 0.009) and to achieve SpO2 92% in room air by 17 min (p=0.001). Aldrete scores were higher in AAI- than in SCP-monitored patients at arrival in PACU (p = 0.035), but Aldrete scores ≥9 were attained in similar times. AAI monitoring can improve titration of and recovery from sevoflurane for LAGB.
2011
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2475905
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact