Abstract BACKGROUND: Achieving the target of 95% colonoscopy completion rate at centres conducting colorectal screening programs is an important issue. Large centres and teaching hospitals employing endoscopists with different levels of training and expertise risk achieving worse results. Deep sedation with propofol in routine colonoscopy could maximize the results of cecal intubation. METHODS: The present study on the experience of a single centre focused on estimating the overall completion rate of colonoscopies performed under routine propofol sedation at a large teaching hospital with many operators involved, and on assessing the factors that influence the success rate of the procedure and how to improve this performance, analyzing the aspects relating to using of deep sedation. Twenty-one endoscopists, classified by their level of specialization in colonoscopic practice, performed 1381 colonoscopies under deep sedation. All actions needed for the anaesthesiologist to restore adequate oxygenation or hemodynamics, even for transient changes, were recorded. RESULTS: The "crude" overall completion rate was 93.3%. This finding shows that with routine deep sedation, the colonoscopy completion rate nears, but still does not reach, the target performance for colonoscopic screening programs, at centers where colonoscopists of difference experience are employed in such programs.Factors interfering with cecal intubation were: inadequate colon cleansing, endoscopists' expertise in colonoscopic practice, patients' body weight under 60 kg or age over 71 years, and the need for active intervention by the anaesthesiologist. The most favourable situation--a patient less than 71 years old with a body weight over 60 kg, an adequate bowel preparation, a "highly experienced specialist" performing the test, and no need for active anaesthesiological intervention during the procedure--coincided with a 98.8% probability of the colonoscopy being completed. CONCLUSIONS: With routine deep sedation, the colonoscopy completion rate nears the target performance for colonoscopic screening programs, at centers where colonoscopists of difference experience are employed in such programs. Organizing the daily workload to prevent negative factors affecting the success rate from occurring in combination may enable up to 85% of incomplete procedures to be converted into successful colonoscopies.

Maximizing the general success of cecal intubation during propofol sedation in a multiendoscopist academic centre.

MARTELLA, BRUNO;
2010

Abstract

Abstract BACKGROUND: Achieving the target of 95% colonoscopy completion rate at centres conducting colorectal screening programs is an important issue. Large centres and teaching hospitals employing endoscopists with different levels of training and expertise risk achieving worse results. Deep sedation with propofol in routine colonoscopy could maximize the results of cecal intubation. METHODS: The present study on the experience of a single centre focused on estimating the overall completion rate of colonoscopies performed under routine propofol sedation at a large teaching hospital with many operators involved, and on assessing the factors that influence the success rate of the procedure and how to improve this performance, analyzing the aspects relating to using of deep sedation. Twenty-one endoscopists, classified by their level of specialization in colonoscopic practice, performed 1381 colonoscopies under deep sedation. All actions needed for the anaesthesiologist to restore adequate oxygenation or hemodynamics, even for transient changes, were recorded. RESULTS: The "crude" overall completion rate was 93.3%. This finding shows that with routine deep sedation, the colonoscopy completion rate nears, but still does not reach, the target performance for colonoscopic screening programs, at centers where colonoscopists of difference experience are employed in such programs.Factors interfering with cecal intubation were: inadequate colon cleansing, endoscopists' expertise in colonoscopic practice, patients' body weight under 60 kg or age over 71 years, and the need for active intervention by the anaesthesiologist. The most favourable situation--a patient less than 71 years old with a body weight over 60 kg, an adequate bowel preparation, a "highly experienced specialist" performing the test, and no need for active anaesthesiological intervention during the procedure--coincided with a 98.8% probability of the colonoscopy being completed. CONCLUSIONS: With routine deep sedation, the colonoscopy completion rate nears the target performance for colonoscopic screening programs, at centers where colonoscopists of difference experience are employed in such programs. Organizing the daily workload to prevent negative factors affecting the success rate from occurring in combination may enable up to 85% of incomplete procedures to be converted into successful colonoscopies.
2010
File in questo prodotto:
File Dimensione Formato  
maximizing.pdf

accesso aperto

Tipologia: Versione editoriale
Licenza: Creative commons
Dimensione 340.98 kB
Formato Adobe PDF
340.98 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2472207
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 15
  • OpenAlex ND
social impact