Radiant panels for heating and cooling are becoming very popular, both in dwellings and in office buildings. In fact they guarantee not only thermal and acoustic comfort but also good energy efficiency due to favourable working temperatures. Such temperatures fit the exploitation of geothermal heat pumps and solar thermal panels, so low temperature difference radiant systems make it possible to increase energy efficiency in buildings. The detailed analysis of thermal performances of radiant panels requires the study of heat flows involving each internal surface of the test room. In this work a climatic room (with radiant panels installed in all surfaces) has been equipped and studied for cooling capacity rating according to standard EN 14240. In addition to the cooling capacity, also heating capacity performances have been investigated by means of tests, adapting the Standard for such a target. Moreover, this study examines radiant and convective thermal loads effects on the global thermal environment.

Sistemi radianti a bassa temperatura: verifica prestazionale e rilevazione dei parametri di comfort mediante prove in camera climatica

DE CARLI, MICHELE;SCARPA, MASSIMILIANO;TOMASI, ROBERTA;ZECCHIN, ROBERTO
2009

Abstract

Radiant panels for heating and cooling are becoming very popular, both in dwellings and in office buildings. In fact they guarantee not only thermal and acoustic comfort but also good energy efficiency due to favourable working temperatures. Such temperatures fit the exploitation of geothermal heat pumps and solar thermal panels, so low temperature difference radiant systems make it possible to increase energy efficiency in buildings. The detailed analysis of thermal performances of radiant panels requires the study of heat flows involving each internal surface of the test room. In this work a climatic room (with radiant panels installed in all surfaces) has been equipped and studied for cooling capacity rating according to standard EN 14240. In addition to the cooling capacity, also heating capacity performances have been investigated by means of tests, adapting the Standard for such a target. Moreover, this study examines radiant and convective thermal loads effects on the global thermal environment.
2009
47° CONVEGNO INTERNAZIONALE AICARR
9788895620534
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2469332
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact