A simple high-performance liquid chromatography method for the determination of the human immunodeficiency virus protease inhibitor atazanavir in human plasma samples was developed and validated. The method involved a rapid and simple solid-phase extraction of atazanavir using Oasis HLB 1cc cartridges, an isocratic reversed-phase liquid chromatography on an XTerra RP18 (150mmx4.6mm, 3.5microm) column, and ultraviolet detection at 203nm. The mobile phase consisted of phosphate buffer (pH 6, 52.5mM) and acetonitrile (43:57, v/v). Up to 48 samples could be measured in one day since the run-time of one sample was 30min. The assay was linear from 0.04 to 10microg/ml with a lower limit of quantification of 0.04microg/ml. The mean absolute recovery of ATV was 98.1%. The method was precise, with both intra-day and inter-day coefficients of variation < or =3.0%, and accurate (deviations ranged from -3.0% to 4.5% and from -3.6% to 4.7% for intra-day and inter-day analysis, respectively). There was no interference from 35 tested potentially co-administrated drugs. This method provides a simple, sensitive, precise and reproducible assay for the therapeutic drug monitoring of atazanavir in clinical routine of laboratories with standard equipment.

Simple determination of the HIV protease inhibitor atazanavir in human plasma by high-performance liquid chromatography with UV detection

LOREGIAN, ARIANNA;PARISI, SAVERIO;PALU', GIORGIO
2006

Abstract

A simple high-performance liquid chromatography method for the determination of the human immunodeficiency virus protease inhibitor atazanavir in human plasma samples was developed and validated. The method involved a rapid and simple solid-phase extraction of atazanavir using Oasis HLB 1cc cartridges, an isocratic reversed-phase liquid chromatography on an XTerra RP18 (150mmx4.6mm, 3.5microm) column, and ultraviolet detection at 203nm. The mobile phase consisted of phosphate buffer (pH 6, 52.5mM) and acetonitrile (43:57, v/v). Up to 48 samples could be measured in one day since the run-time of one sample was 30min. The assay was linear from 0.04 to 10microg/ml with a lower limit of quantification of 0.04microg/ml. The mean absolute recovery of ATV was 98.1%. The method was precise, with both intra-day and inter-day coefficients of variation < or =3.0%, and accurate (deviations ranged from -3.0% to 4.5% and from -3.6% to 4.7% for intra-day and inter-day analysis, respectively). There was no interference from 35 tested potentially co-administrated drugs. This method provides a simple, sensitive, precise and reproducible assay for the therapeutic drug monitoring of atazanavir in clinical routine of laboratories with standard equipment.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2441608
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 21
  • OpenAlex ND
social impact