Background-Three-dimensional electroanatomic voltage mapping offers the potential to identify low-voltage areas that correspond to regions of right ventricular (RV) myocardial loss and fibrofatty replacement in patients with arrhythmogenic RV cardiomyopathy/dysplasia (ARVC/D). Methods and Results-Thirty-one consecutive patients (22 men and 9 women; mean age, 30.8±7 years) who fulfilled the criteria of the Task Force of the European Society of Cardiology and International Society and Federation of Cardiology (ESC/ISFC) for ARVC/D diagnosis after noninvasive clinical evaluation underwent further invasive study including RV electroanatomic voltage mapping and endomyocardial biopsy (EMB) to validate the diagnosis. Multiple RV endocardial, bipolar electrograms (175±23) were sampled during sinus rhythm. Twenty patients (group A; 65%) had an abnormal RV electroanatomic voltage mapping showing ≥1 area (mean 2.25±0.7) with low-voltage values (bipolar electrogram amplitude <0.5 mV), surrounded b...

Three-dimensional electroanatomic voltage mapping increases accuracy of diagnosing arrhythmogenic right ventricular cardiomyopathy/dysplasia

CORRADO, DOMENICO;BASSO, CRISTINA;BAUCE, BARBARA;TARANTINI, GIUSEPPE;NAPODANO, MASSIMO;ILICETO, SABINO;DALIENTO, LUCIANO;NAVA, ANDREA;BUJA, GIANFRANCO;THIENE, GAETANO
2005

Abstract

Background-Three-dimensional electroanatomic voltage mapping offers the potential to identify low-voltage areas that correspond to regions of right ventricular (RV) myocardial loss and fibrofatty replacement in patients with arrhythmogenic RV cardiomyopathy/dysplasia (ARVC/D). Methods and Results-Thirty-one consecutive patients (22 men and 9 women; mean age, 30.8±7 years) who fulfilled the criteria of the Task Force of the European Society of Cardiology and International Society and Federation of Cardiology (ESC/ISFC) for ARVC/D diagnosis after noninvasive clinical evaluation underwent further invasive study including RV electroanatomic voltage mapping and endomyocardial biopsy (EMB) to validate the diagnosis. Multiple RV endocardial, bipolar electrograms (175±23) were sampled during sinus rhythm. Twenty patients (group A; 65%) had an abnormal RV electroanatomic voltage mapping showing ≥1 area (mean 2.25±0.7) with low-voltage values (bipolar electrogram amplitude <0.5 mV), surrounded b...
2005
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2433015
Citazioni
  • ???jsp.display-item.citation.pmc??? 38
  • Scopus 228
  • ???jsp.display-item.citation.isi??? 188
  • OpenAlex ND
social impact