This paper investigates the effects of control-delay minimization in the dynamic performance of the output stage of uninterruptible power supplies (UPSs) by shifting the sampling time of inductor current and output voltage toward the duty-cycle update instant. This paper shows how a small shift of the output-voltage sampling can significantly increase the UPS voltage-loop bandwidth while keeping the same stability margin. Instead, less contribution comes from the delay minimization of the inductor-current sampling, so that current-ripple cancellation techniques are not needed. A detailed model based on the modified Z-transform, which accounts for different time delays in multiloop control, is proposed. The effectiveness of the proposed analysis is demonstrated by simulation and experimental results on a typical industrial three-phase/three-phase 8-kHz 30-kVA UPS prototype. By using two control designs based on the same phase margin, the output-voltage total harmonic distortion with the normalized distorting load is reduced from 6.8% to 5.7%, using a delay of the output voltage sampling equal to 25 mus.

Analysis of control-delay reduction for the improvement of UPS voltage-loop bandwidth

MATTAVELLI, PAOLO;
2008

Abstract

This paper investigates the effects of control-delay minimization in the dynamic performance of the output stage of uninterruptible power supplies (UPSs) by shifting the sampling time of inductor current and output voltage toward the duty-cycle update instant. This paper shows how a small shift of the output-voltage sampling can significantly increase the UPS voltage-loop bandwidth while keeping the same stability margin. Instead, less contribution comes from the delay minimization of the inductor-current sampling, so that current-ripple cancellation techniques are not needed. A detailed model based on the modified Z-transform, which accounts for different time delays in multiloop control, is proposed. The effectiveness of the proposed analysis is demonstrated by simulation and experimental results on a typical industrial three-phase/three-phase 8-kHz 30-kVA UPS prototype. By using two control designs based on the same phase margin, the output-voltage total harmonic distortion with the normalized distorting load is reduced from 6.8% to 5.7%, using a delay of the output voltage sampling equal to 25 mus.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/2268081
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 107
  • ???jsp.display-item.citation.isi??? 85
  • OpenAlex ND
social impact