This study evaluated the characteristics of transient evoked otoacoustic emission (TEOAE) time-frequency (TF) representations from normal and hearing-impaired ears. Linear and non-linear TEOAE recordings from normally-hearing subjects (40) and non-linear recordings from patients with sensorineural hearing loss (SNHL) (40) were analysed using the short-time-Fourier-transform spectrogram, the Gabor spectrogram, and the adaptive spectrogram. The TF representations of the TEOAE recordings indicated a considerable dispersion of energy across frequencies and TEOAE time segments >4.0 ms. The linear and non-linear recordings from the normal subjects showed common frequency peaks. The TF representations from the patients with SNHL indicated that the significantly reduced energy in the mid-to-high TEOAE frequencies did not correlate closely with the threshold elevation. As in the recordings from the normal subjects, a high percentage of the TEOAE cumulative energy was found within a short TEOAE segment (4-14 ms).

Time-frequency analyses of TEOAE recordings from normals and SNHL patients.

MARTINI, ALESSANDRO
2000

Abstract

This study evaluated the characteristics of transient evoked otoacoustic emission (TEOAE) time-frequency (TF) representations from normal and hearing-impaired ears. Linear and non-linear TEOAE recordings from normally-hearing subjects (40) and non-linear recordings from patients with sensorineural hearing loss (SNHL) (40) were analysed using the short-time-Fourier-transform spectrogram, the Gabor spectrogram, and the adaptive spectrogram. The TF representations of the TEOAE recordings indicated a considerable dispersion of energy across frequencies and TEOAE time segments >4.0 ms. The linear and non-linear recordings from the normal subjects showed common frequency peaks. The TF representations from the patients with SNHL indicated that the significantly reduced energy in the mid-to-high TEOAE frequencies did not correlate closely with the threshold elevation. As in the recordings from the normal subjects, a high percentage of the TEOAE cumulative energy was found within a short TEOAE segment (4-14 ms).
2000
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/139400
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 12
  • OpenAlex ND
social impact