Core electron temperature measurements have been performed in the large, high-current RFX reversed field pinch experiment (a = 0.46 m, R = 2 m, target plasma current = 2 MA) with the double filter technique. With this technique the soft x-ray emission is measured by two Si detectors, covered by different Be-filters, and viewing the same region of the plasma. By choosing the filters in such a way that only the emission from the continuum part of the spectrum is measured, the ratio of the two signals is a function of the highest electron temperature along the line of sight of the detectors. With this diagnostic, the electron temperature has been measured in RFX with a bandwidth of approximately 2 kHz. This allows the direct measurement, for the first time in a RFP on a single shot basis, of coherent oscillations, associated with relaxation events and showing under some conditions a sawtooth-like character. The measurements of electron temperature obtained with this method are in good agreement with those performed with other diagnostics.
Electron Temperature Measurements with High Time Resolution in RFX
MARTIN, PIERO;
1996
Abstract
Core electron temperature measurements have been performed in the large, high-current RFX reversed field pinch experiment (a = 0.46 m, R = 2 m, target plasma current = 2 MA) with the double filter technique. With this technique the soft x-ray emission is measured by two Si detectors, covered by different Be-filters, and viewing the same region of the plasma. By choosing the filters in such a way that only the emission from the continuum part of the spectrum is measured, the ratio of the two signals is a function of the highest electron temperature along the line of sight of the detectors. With this diagnostic, the electron temperature has been measured in RFX with a bandwidth of approximately 2 kHz. This allows the direct measurement, for the first time in a RFP on a single shot basis, of coherent oscillations, associated with relaxation events and showing under some conditions a sawtooth-like character. The measurements of electron temperature obtained with this method are in good agreement with those performed with other diagnostics.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.