Background and purpose: For many years deep brain stimulation (DBS) devices relied only on voltage-controlled stimulation (CV), but recently current-controlled devices have been developed and approved for new implants as well as for replacement of CV devices after battery drain. Constant-current (CC) stimulation has been demonstrated to be effective in new implanted parkinsonian and dystonic patients, but the effect of switching to CC therapy in patients chronically stimulated with CV implantable pulse generators (IPGs) has not been assessed. This report shows the results of a consecutive retrospective data collection performed at five Italian centers before and after replacement of constant-voltage with constant-current DBS devices, in order to verify the clinical efficacy and safety of this procedure. Methods: Nineteen patients with Parkinson's disease or dystonic syndrome underwent DBS IPG CV/CC replacement. Clinical features and therapy satisfaction were assessed before surgery, 1 ...

Switching from constant voltage to constant current in deep brain stimulation: a multicenter experience of mixed implants for movement disorders.

Antonini A;Landi A;
2016

Abstract

Background and purpose: For many years deep brain stimulation (DBS) devices relied only on voltage-controlled stimulation (CV), but recently current-controlled devices have been developed and approved for new implants as well as for replacement of CV devices after battery drain. Constant-current (CC) stimulation has been demonstrated to be effective in new implanted parkinsonian and dystonic patients, but the effect of switching to CC therapy in patients chronically stimulated with CV implantable pulse generators (IPGs) has not been assessed. This report shows the results of a consecutive retrospective data collection performed at five Italian centers before and after replacement of constant-voltage with constant-current DBS devices, in order to verify the clinical efficacy and safety of this procedure. Methods: Nineteen patients with Parkinson's disease or dystonic syndrome underwent DBS IPG CV/CC replacement. Clinical features and therapy satisfaction were assessed before surgery, 1 ...
2016
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11577/3313619
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 39
  • ???jsp.display-item.citation.isi??? 37
  • OpenAlex ND
social impact